A basic test of calibration methods for measurement of three-dimensional movements of lower limbs with inertial sensors

Takuma Ando, Takashi Watanabe

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

Measurement of three-dimensional lower limb joint angles are useful to evaluate changes of movements after various lower limb diseases or injuries. However, estimation of three-dimensional angles with inertial measurement units (IMUs) causes errors, especially in abduction/adduction angle and in internal/external rotation angle. This was considered to be caused by difference between the sensor coordinate system and the body coordinate system. In order to solve the problem, various calibration methods of the coordinate system have been proposed. In this paper, three calibration methods, which were selected based on practical application, were examined in estimation of three-dimensional angles of a rigid body model under the 8 attachment conditions of IMU. The Method A determined the body coordinate system by measuring the vertical axis during a standing upright posture and another posture in the sagittal plane. The Method B estimated the sagittal plane and the normal vector of the plane from measured acceleration signals during movement of each segment of the lower limb in the sagittal plane. Method C was similar to Method A, in which postures of vertical and horizontal positions of lower limbs were used. Difference of the coordinate system of the IMU increased significantly RMSE values of estimated angles. Since the Method A and C showed almost same RMSE values as in the case that there was no difference of the coordinate system, the methods are considered to be practical. However, the Method B that used movement in the sagittal plane could not decrease RMSE values in many attachment conditions. Performing the movement in the sagittal plane was considered to be difficult for practical use.

Original languageEnglish
Title of host publication2018 IEEE Life Sciences Conference, LSC 2018
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages211-214
Number of pages4
ISBN (Electronic)9781538667095
DOIs
Publication statusPublished - 2018 Dec 10
Event2018 IEEE Life Sciences Conference, LSC 2018 - Montreal, Canada
Duration: 2018 Oct 282018 Oct 30

Publication series

Name2018 IEEE Life Sciences Conference, LSC 2018

Other

Other2018 IEEE Life Sciences Conference, LSC 2018
Country/TerritoryCanada
CityMontreal
Period18/10/2818/10/30

Keywords

  • Angle
  • Calibration
  • Coordinate system
  • IMU

ASJC Scopus subject areas

  • Signal Processing
  • Medicine (miscellaneous)
  • Health Informatics
  • Instrumentation

Fingerprint

Dive into the research topics of 'A basic test of calibration methods for measurement of three-dimensional movements of lower limbs with inertial sensors'. Together they form a unique fingerprint.

Cite this