TY - JOUR
T1 - A comparative study of ethylene oxide gas, hydrogen peroxide gas plasma, and low-temperature steam formaldehyde sterilization
AU - Kanemitsu, Keiji
AU - Imasaka, Takayuki
AU - Ishikawa, Shiho
AU - Kunishima, Hiroyuki
AU - Harigae, Hideo
AU - Ueno, Kumi
AU - Takemura, Hiromu
AU - Hirayama, Yoshihiro
AU - Kaku, Mitsuo
PY - 2005/5
Y1 - 2005/5
N2 - OBJECTIVE: To compare the efficacies of ethylene oxide gas (EOG), hydrogen peroxide gas plasma (PLASMA), and low-temperature steam formaldehyde (LTSF) sterilization methods. METHODS: The efficacies of EOG, PLASMA, and LTSF sterilization were tested using metal and plastic plates, common medical instruments, and three process challenge devices with narrow lumens. All items were contaminated with Bacillus stearothermophilus spores or used a standard biological indicator. RESULTS: EOG and LTSF demonstrated effective killing of B. stearothermophilus spores, with or without serum, on plates, on instruments, and in process challenge devices. PLASMA failed to adequately sterilize materials on multiple trials in several experiments, including two of three plates, two of three instruments, and all process challenge devices. CONCLUSIONS: Our results suggest that PLASMA sterilization may be unsuccessful under certain conditions, particularly when used for items with complex shapes and narrow lumens. Alternatively, LTSF sterilization demonstrates excellent efficacy and is comparable to EOG sterilization. LTSF could potentially act as a substitute if EOG becomes unavailable due to environmental concerns.
AB - OBJECTIVE: To compare the efficacies of ethylene oxide gas (EOG), hydrogen peroxide gas plasma (PLASMA), and low-temperature steam formaldehyde (LTSF) sterilization methods. METHODS: The efficacies of EOG, PLASMA, and LTSF sterilization were tested using metal and plastic plates, common medical instruments, and three process challenge devices with narrow lumens. All items were contaminated with Bacillus stearothermophilus spores or used a standard biological indicator. RESULTS: EOG and LTSF demonstrated effective killing of B. stearothermophilus spores, with or without serum, on plates, on instruments, and in process challenge devices. PLASMA failed to adequately sterilize materials on multiple trials in several experiments, including two of three plates, two of three instruments, and all process challenge devices. CONCLUSIONS: Our results suggest that PLASMA sterilization may be unsuccessful under certain conditions, particularly when used for items with complex shapes and narrow lumens. Alternatively, LTSF sterilization demonstrates excellent efficacy and is comparable to EOG sterilization. LTSF could potentially act as a substitute if EOG becomes unavailable due to environmental concerns.
UR - http://www.scopus.com/inward/record.url?scp=18844413529&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=18844413529&partnerID=8YFLogxK
U2 - 10.1086/502572
DO - 10.1086/502572
M3 - Article
C2 - 15954488
AN - SCOPUS:18844413529
SN - 0899-823X
VL - 26
SP - 486
EP - 489
JO - Infection Control and Hospital Epidemiology
JF - Infection Control and Hospital Epidemiology
IS - 5
ER -