TY - JOUR
T1 - A position-sensitive γ-ray detector for positron annihilation 2D-ACAR based on metal package photomultiplier tubes
AU - Inoue, Koji
AU - Saito, Haruo
AU - Nagashima, Yasuyuki
AU - Hyodo, Toshio
AU - Nagai, Yasuyoshi
AU - Muramatsu, Shinichi
AU - Nagai, Shota
AU - Masuda, Keisuke
N1 - Funding Information:
This work was supported by a Grant-in-Aid for scientific research (No. 08559003) from the Ministry of Education, Science and Culture of Japan.
PY - 2002/7/21
Y1 - 2002/7/21
N2 - A new position-sensitive γ-ray detector to be used in a two-dimensional angular correlation of positron annihilation radiation (2D-ACAR) apparatus has been developed. It consists of 36 compact position-sensitive photomultiplier tubes (PS-PMT: HAMAMATSU R5900-00-C8), a light guide, and 2676 Bi4Ge3O12 (BGO) scintillator pieces of size 2.6 mm × 2.6 mm × 18 mm. A high detection efficiency for 511 keV γ-ray is achieved with the length of BGO scintillators used. The detection area is about 160 mm × 160 mm. The 288 anode outputs of the PS-PMTs are wired and connected to resistor chains from which 16 outputs (8 outputs each along the X and Y directions) are taken to identify the incident position of the γ-ray. The spatial resolution is about 3 mm (FWHM). The timing signal taken from the last dynodes of the PS-PMTs gives a timing resolution of 7.7 ns (FWHM) for 511 keV positron annihilation γ-rays.
AB - A new position-sensitive γ-ray detector to be used in a two-dimensional angular correlation of positron annihilation radiation (2D-ACAR) apparatus has been developed. It consists of 36 compact position-sensitive photomultiplier tubes (PS-PMT: HAMAMATSU R5900-00-C8), a light guide, and 2676 Bi4Ge3O12 (BGO) scintillator pieces of size 2.6 mm × 2.6 mm × 18 mm. A high detection efficiency for 511 keV γ-ray is achieved with the length of BGO scintillators used. The detection area is about 160 mm × 160 mm. The 288 anode outputs of the PS-PMTs are wired and connected to resistor chains from which 16 outputs (8 outputs each along the X and Y directions) are taken to identify the incident position of the γ-ray. The spatial resolution is about 3 mm (FWHM). The timing signal taken from the last dynodes of the PS-PMTs gives a timing resolution of 7.7 ns (FWHM) for 511 keV positron annihilation γ-rays.
KW - 2D-ACAR
KW - BGO array
KW - Position-sensitive photomultiplier tube
KW - Positron annihilation
KW - γ-ray detector
UR - http://www.scopus.com/inward/record.url?scp=0037151174&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0037151174&partnerID=8YFLogxK
U2 - 10.1016/S0168-9002(02)00390-X
DO - 10.1016/S0168-9002(02)00390-X
M3 - Article
AN - SCOPUS:0037151174
SN - 0168-9002
VL - 487
SP - 471
EP - 476
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
IS - 3
ER -