A study on post-processing for PRML system with AR channel model in perpendicular magnetic recording

Y. Okamoto, S. Funano, H. Osawa, H. Saito, Hiroaki Muraoka, Y. Nakamura

Research output: Contribution to journalConference articlepeer-review

1 Citation (Scopus)

Abstract

The post-processing for PRML system with AR channel model in perpendicular magnetic recording was studied. An interleaved parity check coding was used to determine the error event at the output of Viterbi detector. The experimental results showed that the post-processor improves the linear density of about 55kBPI in a perpendicular magnetic recording.

Original languageEnglish
JournalDigests of the Intermag Conference
Publication statusPublished - 2003 Oct 1
EventIntermag 2003: International Magnetics Conference - Boston, MA, United States
Duration: 2003 Mar 282003 Apr 3

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Fingerprint