TY - JOUR
T1 - Active bending electric endoscope usine shape memory alloy coil actuators
AU - Makishi, Wataru
AU - Matsunaga, Tadao
AU - Esashi, Masayoshi
AU - Haga, Yoichi
PY - 2007
Y1 - 2007
N2 - Bending motions of the tip of a conventional endoscope are controlled from outside the body by wire traction. A shaft of an endoscope should be relatively hard to avoid buckling by wire traction. Therefore, precise operation of the endoscope is difficult in complex shape areas such as the intestine. Furthermore, patients suffer pain during a procedure with an endoscope. An active bending electric endoscope using shape memory alloy (SMA) actuators has been developed. A CCD camera (410,000 pixels) is mounted at the end of the endoscope and the tip has an omni-directional bending mechanism using three SMA coil actuators. The SMA coil actuators contract by supplying electrical current and bend the endoscope. The external diameter of the fabricated endoscope is 5.5 mm. The maximum bending angle of the fabricated endoscope is 90° (Curvature radius: 29 mm). The observation of the inside of a blood vessel model by the CCD imager of a fabricated endoscope was confirmed. The active bending shaft of the fabricated endoscope, which is realized using SMA coil actuators instead of wire traction, is soft. Therefore, using this endoscope, it may be possible to perform precise observations and treatment of deep areas of the human body.
AB - Bending motions of the tip of a conventional endoscope are controlled from outside the body by wire traction. A shaft of an endoscope should be relatively hard to avoid buckling by wire traction. Therefore, precise operation of the endoscope is difficult in complex shape areas such as the intestine. Furthermore, patients suffer pain during a procedure with an endoscope. An active bending electric endoscope using shape memory alloy (SMA) actuators has been developed. A CCD camera (410,000 pixels) is mounted at the end of the endoscope and the tip has an omni-directional bending mechanism using three SMA coil actuators. The SMA coil actuators contract by supplying electrical current and bend the endoscope. The external diameter of the fabricated endoscope is 5.5 mm. The maximum bending angle of the fabricated endoscope is 90° (Curvature radius: 29 mm). The observation of the inside of a blood vessel model by the CCD imager of a fabricated endoscope was confirmed. The active bending shaft of the fabricated endoscope, which is realized using SMA coil actuators instead of wire traction, is soft. Therefore, using this endoscope, it may be possible to perform precise observations and treatment of deep areas of the human body.
KW - Active bending mechanism
KW - CCD camera
KW - Electric endoscope
KW - SMA actuator
UR - http://www.scopus.com/inward/record.url?scp=33847782886&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33847782886&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:33847782886
SN - 1341-8939
VL - 127
SP - 75-81+5
JO - IEEJ Transactions on Sensors and Micromachines
JF - IEEJ Transactions on Sensors and Micromachines
IS - 2
ER -