T1 - Amperometric biosensor based on tyrosinase-conjugated polysacchride hybrid film
T2 - Selective determination of nanomolar neurotransmitters metabolite of 3,4-dihydroxyphenylacetic acid (DOPAC) in biological fluid
AU - Liu, Aihua
AU - Honma, Itaru
AU - Zhou, Haoshen
N1 - Funding Information:
A.L. would like to thank the Japan Society for the Promotion of Science (JSPS) for financial support of this work.
PY - 2005/11/15
Y1 - 2005/11/15
N2 - The amperometric detection of neurotransmitters metabolite of 3,4-dihydroxyphenylacetic acid (DOPAC) was achieved at a tyrosinase-chitosan composite film-modified glassy carbon (GC) electrode. The optimal conditions for the preparation of the biosensor were established. This bio-composite film was characterized by scanning electron microscopy (SEM) and Fourier transformed infrared (FT-IR) spectra, suggesting that chitosan covalently connected to chitosan chains. Electrochemical characterization of the bio-hybrid membrane-covered electrodes were also performed in 0.05 M phosphate buffer solution (pH 6.52) containing neurotransmitters or their derivatives by using cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and amperometry. This simply-prepared protein-polysaccharide hybrid film provides a microenvironment friendly for enzyme loading. The sensor was operated at -0.15 V with a short response time. The current linearly increased with the increasing concentration of DOPAC over the concentration of 6 nM-0.2 mM. The lower detection limit for DOPAC is 3 nM (S/N = 3). The sensitivity of the sensor is 40 μA mM-1. A physiological level of neurotransmitters and their derivatives including dopamine, l-dopa, adrenaline, noradrenaline and homovanillic acid as well as ascorbic acid, uric acid and acetaminophen do not affect the determination of DOPAC.
AB - The amperometric detection of neurotransmitters metabolite of 3,4-dihydroxyphenylacetic acid (DOPAC) was achieved at a tyrosinase-chitosan composite film-modified glassy carbon (GC) electrode. The optimal conditions for the preparation of the biosensor were established. This bio-composite film was characterized by scanning electron microscopy (SEM) and Fourier transformed infrared (FT-IR) spectra, suggesting that chitosan covalently connected to chitosan chains. Electrochemical characterization of the bio-hybrid membrane-covered electrodes were also performed in 0.05 M phosphate buffer solution (pH 6.52) containing neurotransmitters or their derivatives by using cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and amperometry. This simply-prepared protein-polysaccharide hybrid film provides a microenvironment friendly for enzyme loading. The sensor was operated at -0.15 V with a short response time. The current linearly increased with the increasing concentration of DOPAC over the concentration of 6 nM-0.2 mM. The lower detection limit for DOPAC is 3 nM (S/N = 3). The sensitivity of the sensor is 40 μA mM-1. A physiological level of neurotransmitters and their derivatives including dopamine, l-dopa, adrenaline, noradrenaline and homovanillic acid as well as ascorbic acid, uric acid and acetaminophen do not affect the determination of DOPAC.
KW - Amperometric biosensor
KW - Chitosan
KW - DOPAC
KW - Neurotransmitters
KW - Selective detection
KW - Tyrosinase
UR - http://www.scopus.com/inward/record.url?scp=26944448938&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=26944448938&partnerID=8YFLogxK
U2 - 10.1016/j.bios.2005.03.005
DO - 10.1016/j.bios.2005.03.005
M3 - Article
C2 - 15886002
AN - SCOPUS:26944448938
SN - 0956-5663
VL - 21
SP - 809
EP - 816
JO - Biosensors and Bioelectronics
JF - Biosensors and Bioelectronics
IS - 5
ER -