TY - JOUR
T1 - An ultrahigh spatial resolution radiation-imaging detector using 0.1 mm × 0.1 mm pixelated GAGG plate combined with 1 mm channel size Si-PM array
AU - Yamamoto, Seiichi
AU - Kataoka, Jun
AU - Kamada, Kei
AU - Yoshikawa, Akira
N1 - Funding Information:
This work was partly supported by JSPS KAKENHI Grant Number JP18K19909 .
Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2019/3/1
Y1 - 2019/3/1
N2 - Spatial resolution of a pixelated scintillator-based radiation-imaging detector is sometimes limited by the pixel size of the scintillators. We developed a small-size pixelated GAGG scintillator using a dicing method and combined it with a small channel-size Si-PM array for the development of an ultrahigh resolution radiation-imaging detector. The developed pixelated GAGG scintillator had a pixel size of 0.1 mm × 0.1 mm arranged in 0.15-mm separations. It was combined with a Si-PM array made of 1 mm × 1 mm channels to form a radiation-imaging detector. With the developed radiation imaging detectors, the 0.1 mm × 0.1 mm pixels could be resolved for Am-241 alpha particles (5.5 MeV). The spatial resolutions of this imaging detector were better than 0.31-mm FWHM for Am-241 alpha particles and Ca-45 (maximum energy: 0.257 MeV) beta particles. The spatial resolutions for Am-241 gamma photons (60 keV) and Cs-137 X-ray (∼32 keV) were better than 0.6-mm FWHM. Separation of the images of alpha particles and gamma photons was possible using the scintillation decay time difference of GAGG between alpha particles and gamma photons. The developed ultrahigh spatial resolution pixelated GAGG radiation-imaging detector is promising for the imaging of alpha particles, beta particles, low-energy gamma photons and X-ray.
AB - Spatial resolution of a pixelated scintillator-based radiation-imaging detector is sometimes limited by the pixel size of the scintillators. We developed a small-size pixelated GAGG scintillator using a dicing method and combined it with a small channel-size Si-PM array for the development of an ultrahigh resolution radiation-imaging detector. The developed pixelated GAGG scintillator had a pixel size of 0.1 mm × 0.1 mm arranged in 0.15-mm separations. It was combined with a Si-PM array made of 1 mm × 1 mm channels to form a radiation-imaging detector. With the developed radiation imaging detectors, the 0.1 mm × 0.1 mm pixels could be resolved for Am-241 alpha particles (5.5 MeV). The spatial resolutions of this imaging detector were better than 0.31-mm FWHM for Am-241 alpha particles and Ca-45 (maximum energy: 0.257 MeV) beta particles. The spatial resolutions for Am-241 gamma photons (60 keV) and Cs-137 X-ray (∼32 keV) were better than 0.6-mm FWHM. Separation of the images of alpha particles and gamma photons was possible using the scintillation decay time difference of GAGG between alpha particles and gamma photons. The developed ultrahigh spatial resolution pixelated GAGG radiation-imaging detector is promising for the imaging of alpha particles, beta particles, low-energy gamma photons and X-ray.
KW - GAGG
KW - Pixelated
KW - Pulse-shape discrimination
KW - Si-PM array
KW - Ultrahigh spatial resolution
UR - http://www.scopus.com/inward/record.url?scp=85059162811&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85059162811&partnerID=8YFLogxK
U2 - 10.1016/j.nima.2018.12.002
DO - 10.1016/j.nima.2018.12.002
M3 - Article
AN - SCOPUS:85059162811
SN - 0168-9002
VL - 919
SP - 125
EP - 133
JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
ER -