TY - JOUR
T1 - Analysis of contact lengths of strands with Cu sleeves in CICC joints
AU - Nakazawa, Shinobu
AU - Arai, Daichi
AU - Morimura, Toshiya
AU - Miyagi, Daisuke
AU - Tsuda, Makoto
AU - Hamajima, Takataro
AU - Yagai, Tsuyoshi
AU - Nunoya, Yoshihiko
AU - Koizumi, Norikiyo
AU - Takahata, Kazuya
AU - Obana, Tetsuhiro
PY - 2012
Y1 - 2012
N2 - Cable-in-Conduit-Conductor (CICC) is used for the international thermonuclear fusion experimental reactor (ITER) toroidal field (TF) coils. But the critical current of the CICC is measured lower than expected one. This is partly explained by unbalanced current distribution caused by inhomogeneous contact resistances between strands and copper sleeves at joints. Current density in some strands reaches the critical under unbalanced current, and the quench is occurred under smaller transport current than expected one. In order to investigate the contact resistances, we measure the three-dimensional positions of all strands inside the CICC for Large Helical Device (LHD) poloidal field (PF) outer vertical (OV) coil, and evaluate contact parameters such as number and lengths of strands which contact with a copper sleeve. Then, we simulate the strand positions in the CICC using the numerical code which we developed, and compare the contact parameters which evaluated from the measured strand positions and the simulated ones. It is found that the both results are in good agreement, and the developed numerical model is useful for evaluation of the contact parameters. We apply the code to various CIC conductor joints to obtain optimal joint parameters.
AB - Cable-in-Conduit-Conductor (CICC) is used for the international thermonuclear fusion experimental reactor (ITER) toroidal field (TF) coils. But the critical current of the CICC is measured lower than expected one. This is partly explained by unbalanced current distribution caused by inhomogeneous contact resistances between strands and copper sleeves at joints. Current density in some strands reaches the critical under unbalanced current, and the quench is occurred under smaller transport current than expected one. In order to investigate the contact resistances, we measure the three-dimensional positions of all strands inside the CICC for Large Helical Device (LHD) poloidal field (PF) outer vertical (OV) coil, and evaluate contact parameters such as number and lengths of strands which contact with a copper sleeve. Then, we simulate the strand positions in the CICC using the numerical code which we developed, and compare the contact parameters which evaluated from the measured strand positions and the simulated ones. It is found that the both results are in good agreement, and the developed numerical model is useful for evaluation of the contact parameters. We apply the code to various CIC conductor joints to obtain optimal joint parameters.
KW - Cable-in-conduit conductor
KW - Contact length
KW - Joint
KW - Twist pitch
UR - http://www.scopus.com/inward/record.url?scp=84879095985&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84879095985&partnerID=8YFLogxK
U2 - 10.1585/pfr.7.2403143
DO - 10.1585/pfr.7.2403143
M3 - Article
AN - SCOPUS:84879095985
SN - 1880-6821
VL - 7
JO - Plasma and Fusion Research
JF - Plasma and Fusion Research
IS - SPL.ISS.1
M1 - 2403143
ER -