Assessment of a commercially available automatic deformable image registration

Yoshiyuki Katsuta, Noriyuki Kadoya, Yukio Fujita, Yusuke Onozato, Kengo Ito, Tokihiro Yamamoto, Suguru Dobashi, Ken Takeda, Kazuma Kishi, Kiyokazu Satou, Youjiro Ishikawa, Takaya Yamamoto, Maiko Kozumi, Keiichi Jingu, Haruo Matsushita

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

2 Citations (Scopus)

Abstract

Ventilation imaging can be performed using thoracic four dimensional computed tomography (4D-CT) images (max inhale phase and max exhale phase) and deformable image registration (DIR). If this method was administered in multi institution, some institution would use commercially available automatic DIR software. But, there are not many reports about commercially available automatic DIR. In this study, we evaluated the accuracy of a commercially available automatic deformable image registration (DIR) algorithm using 4D-CT images. For evaluating the accuracy of DIR, registration error was calculated by difference between manual displacement and automatic calculated displacement (DIR outputs). A B-spline DIR algorithm implemented in a Velocity AI ver. 2.7.0 software (Velocity Medial, GA, USA) was evaluated. 4D-CT images including 300 landmarks /case, throughout the lung, provided by DIR-lab (www.dir-lab.com). In this study, five patients were studied. The goal of DIR was to find a point to point correspondence between inhale image and exhale image. First, manual displacement was calculated by land mark points between max inhale phase and max exhale phase. Next, DIR outputs were calculated by a Velocity AI. After that, registration error was calculated by difference between manual displacement and DIR outputs. The mean 3D registration error (standard deviation) for the five cases was 2.70 (2.24) mm. Fewer large errors were seen, but the frequent histogram had a peak at 1.5mm of 3D error, and the frequencies decline as one moves away from the peak. The average 3D registration errors for case1 were 0.94 mm for 1.5 mm motion distance magnitude, 1.96 mm for 6.0 mm and 3.70 mm for 9.0 mm, respectively. Our result clearly shows that the accuracy of DIR in Velocity AI was within 3.0 mm. Therefore commercially available automatic DIR may be useful for image-guided radiation therapy, adaptive radiation therapy and ventilation imaging.

Original languageEnglish
Title of host publicationWorld Congress on Medical Physics and Biomedical Engineering
Pages1849-1852
Number of pages4
DOIs
Publication statusPublished - 2013
EventWorld Congress on Medical Physics and Biomedical Engineering - Beijing, China
Duration: 2012 May 262012 May 31

Publication series

NameIFMBE Proceedings
Volume39 IFMBE
ISSN (Print)1680-0737

Conference

ConferenceWorld Congress on Medical Physics and Biomedical Engineering
Country/TerritoryChina
CityBeijing
Period12/5/2612/5/31

Keywords

  • accuracy
  • deformable image registration

Fingerprint

Dive into the research topics of 'Assessment of a commercially available automatic deformable image registration'. Together they form a unique fingerprint.

Cite this