T1 - Assessment of biological effect of minimal acupuncture using causal coherence function between blood pressure and heart rate
AU - Sugita, Norihiro
AU - Seki, Takashi
AU - Yoshizawa, Makoto
AU - Abe, Makoto
AU - Tanaka, Akira
AU - Abe, Ken Ichi
AU - Yambe, Tomoyuki
AU - Nitta, Shin Ichi
PY - 2006
Y1 - 2006
N2 - To assess the effect of acupuncture on the human, 17 healthy volunteers participated in a double-blind randomized crossover clinical trial using real-needle and no-needle seals. In this study, by using systolic blood pressure variability (SBP) and heart rate variability (HR), not only coherence function (K2) between SBP and HR but also two causal coherence functions: K2SBP→HR from SBP to HR and K2 HR→SBP from HR to SBP were introduced to divide causal linearity of the cardiovascular system regarded as a closed-loop system. K2 represents total linearity of the system. K2SBP→HR and K2 HR→SBP correspond to the baroreflex system and the mechanical hemodynamics, respectively. The results showed that K 2SBp→HR over the low frequency band (0.04-0.15Hz) underwent a lot of change in real-needle acupuncture but did not in no-needle acupuncture. And there was difference in K2HR→SBP over the high frequency band (0.15-0.45Hz) immediately after the stimulation of acupuncture. These results have never been obtained from conventional methods dealing with a cardiovascular system as an open-loop system.
AB - To assess the effect of acupuncture on the human, 17 healthy volunteers participated in a double-blind randomized crossover clinical trial using real-needle and no-needle seals. In this study, by using systolic blood pressure variability (SBP) and heart rate variability (HR), not only coherence function (K2) between SBP and HR but also two causal coherence functions: K2SBP→HR from SBP to HR and K2 HR→SBP from HR to SBP were introduced to divide causal linearity of the cardiovascular system regarded as a closed-loop system. K2 represents total linearity of the system. K2SBP→HR and K2 HR→SBP correspond to the baroreflex system and the mechanical hemodynamics, respectively. The results showed that K 2SBp→HR over the low frequency band (0.04-0.15Hz) underwent a lot of change in real-needle acupuncture but did not in no-needle acupuncture. And there was difference in K2HR→SBP over the high frequency band (0.15-0.45Hz) immediately after the stimulation of acupuncture. These results have never been obtained from conventional methods dealing with a cardiovascular system as an open-loop system.
KW - Acupuncture
KW - Blood pressure
KW - Causal coherence function
KW - Heart rate
UR - http://www.scopus.com/inward/record.url?scp=34250722258&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34250722258&partnerID=8YFLogxK
U2 - 10.1109/SICE.2006.314862
DO - 10.1109/SICE.2006.314862
M3 - Conference contribution
AN - SCOPUS:34250722258
SN - 8995003855
SN - 9788995003855
T3 - 2006 SICE-ICASE International Joint Conference
SP - 2895
EP - 2898
BT - 2006 SICE-ICASE International Joint Conference
T2 - 2006 SICE-ICASE International Joint Conference
Y2 - 18 October 2006 through 21 October 2006
ER -