TY - GEN
T1 - Basic experiments on radiation imaging by using Pr:Lu3Al 5O12 (LuAG) small crystalline pixels with various reflector
AU - Kamada, Kei
AU - Tsutsumi, Kousuke
AU - Suzuki, Chisato
AU - Usuki, Yoshiyuki
AU - Yanagida, Takeyuki
AU - Yoshikawa, Akira
AU - Yamamoto, Seiichi
AU - Saito, Fumio
PY - 2007
Y1 - 2007
N2 - Pr:LuAG have good scintillation properties of high energy resolution, very fast 5d-4f emission decay time, higher density and high light yield. In order to apply Pr:LuAG to medical imaging application such PET and PEM, the optimization of light output and energy resolution of scintillators is very important. Especially Therefore, to choose a suited reflector is very important because Pr:LuAG has short emission wave length at 310nm. In this work, we studied spatial and energy resolution of pixilated Pr:LuAG with various reflectors (Teflon tape, ESR, BaSO4) by irradiation of 22Na source. Using the BaSO4 reflector, the light output has increased by ∼210% compared to the ESR reflector, and ∼170% compared to the Teflon tape reflector. The BaSO4 reflector also resulted in the best improvement of the energy resolution up to 12%.
AB - Pr:LuAG have good scintillation properties of high energy resolution, very fast 5d-4f emission decay time, higher density and high light yield. In order to apply Pr:LuAG to medical imaging application such PET and PEM, the optimization of light output and energy resolution of scintillators is very important. Especially Therefore, to choose a suited reflector is very important because Pr:LuAG has short emission wave length at 310nm. In this work, we studied spatial and energy resolution of pixilated Pr:LuAG with various reflectors (Teflon tape, ESR, BaSO4) by irradiation of 22Na source. Using the BaSO4 reflector, the light output has increased by ∼210% compared to the ESR reflector, and ∼170% compared to the Teflon tape reflector. The BaSO4 reflector also resulted in the best improvement of the energy resolution up to 12%.
UR - http://www.scopus.com/inward/record.url?scp=48349109213&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=48349109213&partnerID=8YFLogxK
U2 - 10.1109/NSSMIC.2007.4437265
DO - 10.1109/NSSMIC.2007.4437265
M3 - Conference contribution
AN - SCOPUS:48349109213
SN - 1424409233
SN - 9781424409235
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 1417
EP - 1420
BT - 2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC
T2 - 2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC
Y2 - 27 October 2007 through 3 November 2007
ER -