TY - JOUR
T1 - Bayesian modeling of virus removal efficiency in wastewater treatment processes
AU - Ito, T.
AU - Kato, T.
AU - Takagishi, K.
AU - Okabe, S.
AU - Sano, D.
N1 - Publisher Copyright:
© IWA Publishing 2015 Water Science & Technology.
PY - 2015/11
Y1 - 2015/11
N2 - Left-censored datasets of virus density in wastewater samples make it difficult to evaluate the virus removal efficiency in wastewater treatment processes. In the present study, we modeled the probabilistic distribution of virus removal efficiency in a wastewater treatment process with a Bayesian approach, and investigated how many detect samples in influent and effluent are necessary for accurate estimation. One hundred left-censored data of virus density in wastewater (influent and effluent) were artificially generated based on assumed log-normal distributions and the posterior predictive distribution of virus density, and the log-ratio distribution were estimated. The estimation accuracy of distributions was quantified by Bhattacharyya coefficient. When it is assumed that the accurate estimation of posterior predictive distributions is possible when a 100% positive rate is obtained for 12 pairs of influent and effluent, 11 out of 144, 60 out of 324, and 201 out of 576 combinations of detect samples gave an accurate estimation at the significant level of 0.01 in a Kruskal-Wallis test when the total sample number was 12, 18, and 24, respectively. The combinations with the minimum number of detect samples were (12, 9), (16, 10), and (21, 8) when the total sample number was 12, 18, and 24, respectively.
AB - Left-censored datasets of virus density in wastewater samples make it difficult to evaluate the virus removal efficiency in wastewater treatment processes. In the present study, we modeled the probabilistic distribution of virus removal efficiency in a wastewater treatment process with a Bayesian approach, and investigated how many detect samples in influent and effluent are necessary for accurate estimation. One hundred left-censored data of virus density in wastewater (influent and effluent) were artificially generated based on assumed log-normal distributions and the posterior predictive distribution of virus density, and the log-ratio distribution were estimated. The estimation accuracy of distributions was quantified by Bhattacharyya coefficient. When it is assumed that the accurate estimation of posterior predictive distributions is possible when a 100% positive rate is obtained for 12 pairs of influent and effluent, 11 out of 144, 60 out of 324, and 201 out of 576 combinations of detect samples gave an accurate estimation at the significant level of 0.01 in a Kruskal-Wallis test when the total sample number was 12, 18, and 24, respectively. The combinations with the minimum number of detect samples were (12, 9), (16, 10), and (21, 8) when the total sample number was 12, 18, and 24, respectively.
KW - Bayesian model
KW - Left-censored data
KW - Truncated log-normal distribution
KW - Virus removal efficiency
KW - Wastewater treatment
UR - http://www.scopus.com/inward/record.url?scp=84954504815&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84954504815&partnerID=8YFLogxK
U2 - 10.2166/wst.2015.402
DO - 10.2166/wst.2015.402
M3 - Article
C2 - 26540540
AN - SCOPUS:84954504815
SN - 0273-1223
VL - 72
SP - 1789
EP - 1795
JO - Water Science and Technology
JF - Water Science and Technology
IS - 10
ER -