Abstract
The behavior of helium-gas release from helium-implanted 9Cr martensitic steels (500 appm implanted at 873 K) during tensile testing at 873 K was studied. Modified 9Cr-1Mo, low-activation 9Cr-2W and 9Cr-0.5V were investigated. Cold-worked AISI 316 austenitic stainless steel was also investigated as a reference which was susceptible helium embrittlement at high temperature. A helium release peak was observed at the moment of rupture in all the specimens. The total quantity of helium released from these 9Cr steels was in the same range but smaller than that of 316CW steel. Helium gas in the 9Cr steels should be considered to remain in the matrix at their lath-packets even if deformed at 873 K. This is the reason why the martensitic steels have high resistance to helium embrittlement.
Original language | English |
---|---|
Pages (from-to) | 720-724 |
Number of pages | 5 |
Journal | Journal of Nuclear Materials |
Volume | 212-215 |
Issue number | PART 1 |
DOIs | |
Publication status | Published - 1994 Sept |
ASJC Scopus subject areas
- Nuclear and High Energy Physics
- Materials Science(all)