TY - JOUR
T1 - Can the artificial heart make the circulation become fractal?
AU - Yambe, T.
AU - Nanka, S.
AU - Naganuma, S.
AU - Kobayashi, S.
AU - Akiho, H.
AU - Kakinuma, Y.
AU - Ohsawa, N.
AU - Nitta, S.
AU - Fukuju, T.
AU - Miura, M.
AU - Uchida, N.
AU - Tabayashi, K.
AU - Tanaka, A.
AU - Yoshizumi, N.
AU - Abe, K.
AU - Takayasu, M.
AU - Takayasu, H.
AU - Yoshizawa, M.
AU - Takeda, H.
PY - 1995
Y1 - 1995
N2 - In order to analyze the hemodynamic parameters in prosthetic circulation as an entity and not as decomposed parts, non linear mathematical analyzing techniques, including the fractal dimension analyzing theory, were utilized. Two pneumatically actuated ventricular assist devices were implanted, as biventricular bypasses (BVB), in chronic animal experiments, using four healthy adult goats. For the comparison between the natural and prosthetic circulation in the same animals, the BVB type complete prosthetic circulation model with ventricular fibrillation, was adopted. All hemodynamic parameters with natural and prosthetic circulation were recorded under awake conditions, and calculated with a personal computer system. Using the non-linear mathematical technique, the arterial blood pressure waveform was embedded into the return map as the beat-to-beat time series data and fractal dimension analysis were performed to analyze the reconstructed attractor. By the use of the Box counting method, fractal dimension analysis of the hemodynamics was performed. Return map of the hemodynamics during natural and artificial circulation showed fractal characteristics, and fractal dimension analysis of the arterial blood pressure revealed the fact that lower dimensional fractal dynamics were evident during prosthetic circulation. Fractal time series data is suggested to have robustness and error resistance, thus our results suggest that the circulatory regulatory system with an artificial heart may have these desired characteristics.
AB - In order to analyze the hemodynamic parameters in prosthetic circulation as an entity and not as decomposed parts, non linear mathematical analyzing techniques, including the fractal dimension analyzing theory, were utilized. Two pneumatically actuated ventricular assist devices were implanted, as biventricular bypasses (BVB), in chronic animal experiments, using four healthy adult goats. For the comparison between the natural and prosthetic circulation in the same animals, the BVB type complete prosthetic circulation model with ventricular fibrillation, was adopted. All hemodynamic parameters with natural and prosthetic circulation were recorded under awake conditions, and calculated with a personal computer system. Using the non-linear mathematical technique, the arterial blood pressure waveform was embedded into the return map as the beat-to-beat time series data and fractal dimension analysis were performed to analyze the reconstructed attractor. By the use of the Box counting method, fractal dimension analysis of the hemodynamics was performed. Return map of the hemodynamics during natural and artificial circulation showed fractal characteristics, and fractal dimension analysis of the arterial blood pressure revealed the fact that lower dimensional fractal dynamics were evident during prosthetic circulation. Fractal time series data is suggested to have robustness and error resistance, thus our results suggest that the circulatory regulatory system with an artificial heart may have these desired characteristics.
KW - Box-counting method
KW - Chaos
KW - Deterministic chaos
KW - Fractal
KW - Fractal dimension
KW - Total artificial heart
UR - http://www.scopus.com/inward/record.url?scp=0029044519&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0029044519&partnerID=8YFLogxK
U2 - 10.1177/039139889501800403
DO - 10.1177/039139889501800403
M3 - Article
C2 - 8530198
AN - SCOPUS:0029044519
SN - 0391-3988
VL - 18
SP - 190
EP - 196
JO - International Journal of Artificial Organs
JF - International Journal of Artificial Organs
IS - 4
ER -