Combination of a high resolution detector with small fOV and a low resolution detector with large FOV for high resolution and quantitative SPECT

Tsutomu Zeniya, Hiroshi Watabe, Hiroyuki Kudo, Yoshiyuki Hirano, Kotaro Minato, Hidehiro Iida

Research output: Chapter in Book/Report/Conference proceedingConference contribution

3 Citations (Scopus)

Abstract

SPECT using compact high resolution detector or pinhole collimator allows to image physiological functions with high resolution. However, when region-of-interest (ROI) is smaller than the object, the projection data are truncated due to radioisotope outside ROI. The truncation causes artifact and overestimation, which decrease quantitative accuracy. In theory, to eliminate the artifact and the overestimation due to truncation, the untruncated data from another large field-of-view (FOV) detector can be used even if the detector has low resolution. This study was aimed at evaluating feasibility of combination of a small FOV high resolution detector and a large FOV low resolution detector in clinical circumstance. This evaluation was performed by computer simulation with a numerical torso phantom. We tested whether the image in a selected small ROI (in this case, ROI was heart) can be obtained with high resolution and without artifact and overestimation. The small FOV detector with high resolution was with 1.14-mm resolution, 80-mm FOV and parallel collimator. The whole of heart was included in this FOV, but the surrounding area was truncated. The large FOV detector with low resolution has 9-mm resolution, 360-mm FOV and parallel collimator like conventional clinical SPECT. The untruncated projections including the whole of thorax were acquired by this detector. Gaussian noises were added to allprojection data. Data from the small detector were reconstructedby maximum likelihood expectation maximization (MLEM) as iterative method, on the reconstruction matrix large enough to contain the whole of thorax. The reconstructed image from the large FOV detector was used as an initial image in iterative reconstruction. The image obtained by our proposed method had high resolution and the counts almost equivalent to that of original image in the small ROI. In conclusion, this result suggests feasibility of the combination of two detectors with small and large FOV to quantitatively obtain high-resolution image of a selected small ROI with clinical SPECT.

Original languageEnglish
Title of host publication2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
Pages5229-5231
Number of pages3
DOIs
Publication statusPublished - 2008
Externally publishedYes
Event2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008 - Dresden, Germany
Duration: 2008 Oct 192008 Oct 25

Publication series

NameIEEE Nuclear Science Symposium Conference Record
ISSN (Print)1095-7863

Other

Other2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
Country/TerritoryGermany
CityDresden
Period08/10/1908/10/25

ASJC Scopus subject areas

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Combination of a high resolution detector with small fOV and a low resolution detector with large FOV for high resolution and quantitative SPECT'. Together they form a unique fingerprint.

Cite this