TY - JOUR
T1 - Comparative investigation on the characteristics of glow discharge plasma using glow discharge mass spectrometry and glow discharge optical emission spectrometry
AU - Wagatsuma, Kazuaki
AU - Saka, Takashi
AU - Yamaguchi, Mika
AU - Ito, Kiyotaka
PY - 2002/1/1
Y1 - 2002/1/1
N2 - In glow discharge mass spectrometry (GDMS) and glow discharge optical emission spectrometry (GDOES), variations in the signal intensities against the discharge parameters: current, voltage, and the pressure of plasma gas, are compared to clarify their excitation/ionization processes responsible to each signal. The behaviors are dependent on the discharge mode, i.e., constant-voltage and constant-pressure conditions. Under the constant-voltage conditions where the gas pressure is varied, the ion intensities in GDMS have a maximum and then decrease at higher discharge currents, while the emission intensities in GDOES monotonically increase along with the discharge current. On the other hand, similar dependence of their signal intensities on the discharge current is observed under the constant-pressure conditions. These results indicate that the transport process of analyte ions produced in the plasma play an important role in determining the ion intensities in GDMS.
AB - In glow discharge mass spectrometry (GDMS) and glow discharge optical emission spectrometry (GDOES), variations in the signal intensities against the discharge parameters: current, voltage, and the pressure of plasma gas, are compared to clarify their excitation/ionization processes responsible to each signal. The behaviors are dependent on the discharge mode, i.e., constant-voltage and constant-pressure conditions. Under the constant-voltage conditions where the gas pressure is varied, the ion intensities in GDMS have a maximum and then decrease at higher discharge currents, while the emission intensities in GDOES monotonically increase along with the discharge current. On the other hand, similar dependence of their signal intensities on the discharge current is observed under the constant-pressure conditions. These results indicate that the transport process of analyte ions produced in the plasma play an important role in determining the ion intensities in GDMS.
UR - http://www.scopus.com/inward/record.url?scp=0036026506&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036026506&partnerID=8YFLogxK
U2 - 10.1039/b204747k
DO - 10.1039/b204747k
M3 - Article
AN - SCOPUS:0036026506
SN - 0267-9477
VL - 17
SP - 1359
EP - 1362
JO - Journal of Analytical Atomic Spectrometry
JF - Journal of Analytical Atomic Spectrometry
IS - 10
ER -