TY - JOUR
T1 - Comparative study of treatment for distal radius fractures with two different palmar locking plates
AU - Tanaka, H.
AU - Hatta, T.
AU - Sasajima, K.
AU - Itoi, E.
AU - Aizawa, T.
N1 - Publisher Copyright:
© The British Society for Surgery of the Hand.
PY - 2014/6
Y1 - 2014/6
N2 - Few randomized trials have shown how the placement of a palmar locking plate affects outcomes. The purpose of this study was to compare clinical and radiological outcomes of fixation using locking plates with different concepts for placement relative to the watershed line in a prospective randomized trial. Sixty-four patients with a displaced distal radius fracture were divided into two groups according to the plates used for fixation: distal-type (AcuLocTM, Group A) and proximal-type (VariAxTM, Group V). Wrist function including the range of motion and grip strength was compared at 1, 2, 3 and 6 months postoperatively. Loss of reduction was assessed radiologically. Both groups demonstrated overall satisfactory function at 6 months with no significant difference found between the groups. Minimal loss of reduction was demonstrated in both groups. Internal fixation using the palmar locking plates with two different placements provided satisfactory outcomes at 6-month follow-up, but our results indicate that plates placed distal to the watershed line may delay recovery of wrist motion.
AB - Few randomized trials have shown how the placement of a palmar locking plate affects outcomes. The purpose of this study was to compare clinical and radiological outcomes of fixation using locking plates with different concepts for placement relative to the watershed line in a prospective randomized trial. Sixty-four patients with a displaced distal radius fracture were divided into two groups according to the plates used for fixation: distal-type (AcuLocTM, Group A) and proximal-type (VariAxTM, Group V). Wrist function including the range of motion and grip strength was compared at 1, 2, 3 and 6 months postoperatively. Loss of reduction was assessed radiologically. Both groups demonstrated overall satisfactory function at 6 months with no significant difference found between the groups. Minimal loss of reduction was demonstrated in both groups. Internal fixation using the palmar locking plates with two different placements provided satisfactory outcomes at 6-month follow-up, but our results indicate that plates placed distal to the watershed line may delay recovery of wrist motion.
KW - Distal radius fracture
KW - palmar locking plate
KW - palmar prominence
KW - range of motion
UR - http://www.scopus.com/inward/record.url?scp=84974604954&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84974604954&partnerID=8YFLogxK
U2 - 10.1177/1753193415625830
DO - 10.1177/1753193415625830
M3 - Article
C2 - 26773962
AN - SCOPUS:84974604954
SN - 1753-1934
VL - 41
SP - 536
EP - 542
JO - Journal of Hand Surgery: European Volume
JF - Journal of Hand Surgery: European Volume
IS - 5
ER -