TY - GEN
T1 - Comparing contact pressure induced by a conventional complete denture and an implant-retained overdenture
AU - Chen, Junning
AU - Ahmad, Rohana
AU - Swain, Michael V.
AU - Li, Wei
AU - Suenaga, Hanako
AU - Li, Qing
PY - 2014
Y1 - 2014
N2 - Implant-retained overdenture has been widely applied as a solution to edentulous ageing; however, a major concern for the denture wearers is bone resorption induced by the prosthetic interaction with soft tissue and bone. Early studies have revealed that the bone resorption is associated with the disturbance to the mucosa blood flow. This study aimed to investigate the contact pressure induced by an implant-retained overdenture, compared to a conventional complete denture without implants, which implies the potential bone resorption for clinical investigation. A three-dimensional finite element model of a full jaw, including mandible bone, mucosa, and denture, was created through a reverse engineering method based on CBCT images, in which the hyperelastic behaviour of mucosa was determined by curve-fitting to the clinical measurement, for a more realistic response. It is found that the location of the bone loss differed between the implant retained and non-implant complete dentures. With the implants, the denture displaced more at posterior ends towards the mucosa bearing area, leading to higher contact pressure accounted for more severe local bone loss.
AB - Implant-retained overdenture has been widely applied as a solution to edentulous ageing; however, a major concern for the denture wearers is bone resorption induced by the prosthetic interaction with soft tissue and bone. Early studies have revealed that the bone resorption is associated with the disturbance to the mucosa blood flow. This study aimed to investigate the contact pressure induced by an implant-retained overdenture, compared to a conventional complete denture without implants, which implies the potential bone resorption for clinical investigation. A three-dimensional finite element model of a full jaw, including mandible bone, mucosa, and denture, was created through a reverse engineering method based on CBCT images, in which the hyperelastic behaviour of mucosa was determined by curve-fitting to the clinical measurement, for a more realistic response. It is found that the location of the bone loss differed between the implant retained and non-implant complete dentures. With the implants, the denture displaced more at posterior ends towards the mucosa bearing area, leading to higher contact pressure accounted for more severe local bone loss.
KW - Bone resorption
KW - Complete denture
KW - Contact pressure
KW - Hyperelastic pressure
KW - Non-linear
UR - http://www.scopus.com/inward/record.url?scp=84902075794&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84902075794&partnerID=8YFLogxK
U2 - 10.4028/www.scientific.net/AMM.553.384
DO - 10.4028/www.scientific.net/AMM.553.384
M3 - Conference contribution
AN - SCOPUS:84902075794
SN - 9783038350682
T3 - Applied Mechanics and Materials
SP - 384
EP - 389
BT - Advances in Computational Mechanics
PB - Trans Tech Publications
T2 - 1st Australasian Conference on Computational Mechanics, ACCM 2013
Y2 - 3 October 2013 through 4 October 2013
ER -