T1 - Computational design of vibration pumping device for artificial heart
AU - Kawano, Satoyuki
AU - Kamijo, Kenjiro
AU - Yamakami, Junko
AU - Hashimoto, Hiroyuki
AU - Yambe, Tomoyuki
AU - Nitta, Shin Ichi
PY - 1998
Y1 - 1998
N2 - To develop the prototype vibration pumping device for an artificial heart (Hashimoto et al., 1994), the flow patterns in the casing were analyzed experimentally and numerically from the viewpoint of biomechanical engineering. Considering not only the mechanical performance of the pump but also the hemolysis was very important to design the artificial heart. In the present study, the curvilinear coordinate transformation technique and the finite difference technique were used to numerically solve the unsteady, incompressible and axisymmetric Navier-Stokes equations for the flow field in the various casing configurations of the vibration pumping device. The validity of numerical analysis was confirmed by comparison with the experimental data obtained by the flow visualization technique. Furthermore, the strong dependence of the hemolysis on the flow patterns in the casing was recognized. In particular, the relationship between the vorticity field in the casing and the hemolysis was elucidated. The results obtained here would provide the useful suggestions for future research and the basic design concept of vibration pumping device for the left ventricular assist device.
AB - To develop the prototype vibration pumping device for an artificial heart (Hashimoto et al., 1994), the flow patterns in the casing were analyzed experimentally and numerically from the viewpoint of biomechanical engineering. Considering not only the mechanical performance of the pump but also the hemolysis was very important to design the artificial heart. In the present study, the curvilinear coordinate transformation technique and the finite difference technique were used to numerically solve the unsteady, incompressible and axisymmetric Navier-Stokes equations for the flow field in the various casing configurations of the vibration pumping device. The validity of numerical analysis was confirmed by comparison with the experimental data obtained by the flow visualization technique. Furthermore, the strong dependence of the hemolysis on the flow patterns in the casing was recognized. In particular, the relationship between the vorticity field in the casing and the hemolysis was elucidated. The results obtained here would provide the useful suggestions for future research and the basic design concept of vibration pumping device for the left ventricular assist device.
UR - http://www.scopus.com/inward/record.url?scp=0347151364&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0347151364&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:0347151364
SN - 0277-027X
VL - 377-2
SP - 51
EP - 56
JO - American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP
JF - American Society of Mechanical Engineers, Pressure Vessels and Piping Division (Publication) PVP
IS - 0
ER -