Condition monitoring of the material test facility using vibration and ultrasonic measurements

Hisashi Sato, Yousuke Tsujimoto, Makoto Takahashi, Masaharu Kitamura

Research output: Contribution to journalConference articlepeer-review

Abstract

In the present study, the vibration and ultrasonic measurements have been applied to a high flow rate pump installed in the SSBF in order to develop the monitoring and diagnosis methods. The vibration of the casing of the canned pump is measured by using the laser vibration sensor. The frequency domain analyses have been applied to the measured signals. The measurement results showed the validity of the proposed method to monitor the state of the high flow rate pump.

Original languageEnglish
Pages (from-to)963-968
Number of pages6
JournalKey Engineering Materials
Volume261-263
Issue numberII
Publication statusPublished - 2004
EventAdvances in Fracture and Failure Prevention: Proceedings of the Fifth International Conference on Fracture and Strength of Solids (FEOFS2003): Second International Conference on Physics and Chemistry of Fracture and Failure Prevention (2nd ICPCF) - Sendai, Japan
Duration: 2003 Oct 202003 Oct 22

Keywords

  • Condition monitoring
  • Spectrum analysis
  • Ultrasonic
  • Vibration

Fingerprint

Dive into the research topics of 'Condition monitoring of the material test facility using vibration and ultrasonic measurements'. Together they form a unique fingerprint.