TY - JOUR
T1 - Construction of System for Support of Multifacility IVR Dose Analysis and Research
AU - Sun, Lue
AU - Hitomi, Go
AU - Futatsuya, Koichiro
AU - Kato, Mamoru
AU - Kawauchi, Satoru
AU - Morota, Koichi
AU - Tsukamoto, Atsuko
AU - Hayakawa, Mikito
AU - Sakae, Takeji
AU - Matsumaru, Yuji
AU - Chida, Koichi
AU - Moritake, Takashi
PY - 2015/12/1
Y1 - 2015/12/1
N2 - Although measurement and management of angiographic entrance skin dose (ESD) are deemed extremely important, accurate determination of maximum ESD and its location is generally difficult because of the dependence on therapeutic technique and position. Following our development of body-mounted gear bearing radiophotoluminescence glass dosimeter (RPLD) arrays for direct measurement of ESD in cranial and cardiovascular angiography and interventional radiology (IVR), our focus next turned to the limited number of facilities equipped to read RPLD outputs and the need for methods to effectively provide feedback to clinical facilities. As described here, we first constructed an RPLD reading facility capable of sending and receiving RPLDs by post, offering the potential to enable utilization of the developed gear at all hospitals in Japan that perform angiography and IVR. We next developed specialized web-based system to generate dose maps from RPLD dose data, thereby enabling any facility to perform trial system analysis, evaluation, and implementation; and investigated the results and related problems.
AB - Although measurement and management of angiographic entrance skin dose (ESD) are deemed extremely important, accurate determination of maximum ESD and its location is generally difficult because of the dependence on therapeutic technique and position. Following our development of body-mounted gear bearing radiophotoluminescence glass dosimeter (RPLD) arrays for direct measurement of ESD in cranial and cardiovascular angiography and interventional radiology (IVR), our focus next turned to the limited number of facilities equipped to read RPLD outputs and the need for methods to effectively provide feedback to clinical facilities. As described here, we first constructed an RPLD reading facility capable of sending and receiving RPLDs by post, offering the potential to enable utilization of the developed gear at all hospitals in Japan that perform angiography and IVR. We next developed specialized web-based system to generate dose maps from RPLD dose data, thereby enabling any facility to perform trial system analysis, evaluation, and implementation; and investigated the results and related problems.
UR - http://www.scopus.com/inward/record.url?scp=85003412886&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85003412886&partnerID=8YFLogxK
U2 - 10.6009/jjrt.2015_JSRT_71.12.1241
DO - 10.6009/jjrt.2015_JSRT_71.12.1241
M3 - Article
C2 - 26685837
AN - SCOPUS:85003412886
SN - 0369-4305
VL - 71
SP - 1241
EP - 1247
JO - Nihon Hoshasen Gijutsu Gakkai zasshi
JF - Nihon Hoshasen Gijutsu Gakkai zasshi
IS - 12
ER -