TY - GEN
T1 - Controlling methods of a newly developed extra aortic counter-pulsation device using shape memory alloy fibers
AU - Hashem, Mohamed O.
AU - Yamada, A.
AU - Tsuboko, Y.
AU - Muira, H.
AU - Homma, D.
AU - Shiraishi, Y.
AU - Yambe, T.
PY - 2013
Y1 - 2013
N2 - Diastolic counter-pulsation has been used to provide circulatory augmentation for short term cardiac support. The success of intra-aortic balloon pump (IABP) therapy has generated interest in long term counter-pulsation strategies to treat heart failure patients. The authors have been developing a totally implantable extra aortic pulsation device for the circulatory support of heart failure patients, using 150μm Ni-Ti anisotropic shape memory alloy (SMA) fibers. These fibers contract by Joule heating with an electric current supply. The special features of our design are as follow: non blood contacting, extra aortic pulsation function synchronizing with the native heart, a wrapping mechanical structure for the aorta in order to achieve its assistance as the aortomyoplsty and the extra aortic balloon pump. The device consisted of rubber silicone wall plates, serially connected for radial contraction. We examined the contractile function of the device, as well as it controlling methods; the phase delay parameter and the pulse width modulation, in a systemic mock circulatory system, with a pneumatically driven silicone left ventricle model, arterial rubber tubing, a peripheral resistance unit, and a venous reservoir. The device was secured around the aortic tubing with a counter-pulsation mode of 1-4 against the heartbeat. Pressure and flow waveforms were measured at the aortic outflow, as well as its driving condition of the contraction phase width and the phase delay. The device achieved its variable phase control for co-pulsation or counter-pulsation modes by changing the phase delay of the SMA fibers. Peak diastolic pressure significantly augmented, mean flow increased (p<0.05) according to the pulse width modulation. Therefore the newly developed extra aortic counter-pulsation device using SMA fibers, through it controlling methods indicated its promising alternative extra aortic approach for non-blood contacting cardiovascular circulatory support.
AB - Diastolic counter-pulsation has been used to provide circulatory augmentation for short term cardiac support. The success of intra-aortic balloon pump (IABP) therapy has generated interest in long term counter-pulsation strategies to treat heart failure patients. The authors have been developing a totally implantable extra aortic pulsation device for the circulatory support of heart failure patients, using 150μm Ni-Ti anisotropic shape memory alloy (SMA) fibers. These fibers contract by Joule heating with an electric current supply. The special features of our design are as follow: non blood contacting, extra aortic pulsation function synchronizing with the native heart, a wrapping mechanical structure for the aorta in order to achieve its assistance as the aortomyoplsty and the extra aortic balloon pump. The device consisted of rubber silicone wall plates, serially connected for radial contraction. We examined the contractile function of the device, as well as it controlling methods; the phase delay parameter and the pulse width modulation, in a systemic mock circulatory system, with a pneumatically driven silicone left ventricle model, arterial rubber tubing, a peripheral resistance unit, and a venous reservoir. The device was secured around the aortic tubing with a counter-pulsation mode of 1-4 against the heartbeat. Pressure and flow waveforms were measured at the aortic outflow, as well as its driving condition of the contraction phase width and the phase delay. The device achieved its variable phase control for co-pulsation or counter-pulsation modes by changing the phase delay of the SMA fibers. Peak diastolic pressure significantly augmented, mean flow increased (p<0.05) according to the pulse width modulation. Therefore the newly developed extra aortic counter-pulsation device using SMA fibers, through it controlling methods indicated its promising alternative extra aortic approach for non-blood contacting cardiovascular circulatory support.
UR - http://www.scopus.com/inward/record.url?scp=84886533664&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84886533664&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2013.6610107
DO - 10.1109/EMBC.2013.6610107
M3 - Conference contribution
C2 - 24110294
AN - SCOPUS:84886533664
SN - 9781457702167
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 2740
EP - 2743
BT - 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
T2 - 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
Y2 - 3 July 2013 through 7 July 2013
ER -