T1 - Correlation between Reynolds number and eccentricity effect in stenosed artery models
AU - Javadzadegan, Ashkan
AU - Shimizu, Yasutomo
AU - Behnia, Masud
AU - Ohta, Makoto
PY - 2013
Y1 - 2013
N2 - BACKGROUND: Flow recirculation and shear strain are physiological processes within coronary arteries which are associated with pathogenic biological pathways. Distinct Quite apart from coronary stenosis severity, lesion eccentricity can cause flow recirculation and affect shear strain levels within human coronary arteries. OBJECTIVE: The aim of this study is to analyse the effect of lesion eccentricity on the transient flow behaviour in a model of a coronary artery and also to investigate the correlation between Reynolds number (Re) and the eccentricity effect on flow behaviour. METHODS: A transient particle image velocimetry (PIV) experiment was implemented in two silicone based models with 70% diameter stenosis, one with eccentric stenosis and one with concentric stenosis. RESULTS: At different times throughout the flow cycle, the eccentric model was always associated with a greater recirculation zone length, maximum shear strain rate and maximum axial velocity; however, the highest and lowest impacts of eccentricity were on the recirculation zone length and maximum shear strain rate, respectively. Analysis of the results revealed a negative correlation between the Reynolds number (Re) and the eccentricity effect on maximum axial velocity, maximum shear strain rate and recirculation zone length. CONCLUSIONS: As Re number increases the eccentricity effect on the flow behavior becomes negligible.
AB - BACKGROUND: Flow recirculation and shear strain are physiological processes within coronary arteries which are associated with pathogenic biological pathways. Distinct Quite apart from coronary stenosis severity, lesion eccentricity can cause flow recirculation and affect shear strain levels within human coronary arteries. OBJECTIVE: The aim of this study is to analyse the effect of lesion eccentricity on the transient flow behaviour in a model of a coronary artery and also to investigate the correlation between Reynolds number (Re) and the eccentricity effect on flow behaviour. METHODS: A transient particle image velocimetry (PIV) experiment was implemented in two silicone based models with 70% diameter stenosis, one with eccentric stenosis and one with concentric stenosis. RESULTS: At different times throughout the flow cycle, the eccentric model was always associated with a greater recirculation zone length, maximum shear strain rate and maximum axial velocity; however, the highest and lowest impacts of eccentricity were on the recirculation zone length and maximum shear strain rate, respectively. Analysis of the results revealed a negative correlation between the Reynolds number (Re) and the eccentricity effect on maximum axial velocity, maximum shear strain rate and recirculation zone length. CONCLUSIONS: As Re number increases the eccentricity effect on the flow behavior becomes negligible.
KW - coronary artery
KW - eccentricity
KW - Particle image velocimetry
KW - Reynolds number
KW - stenosis
UR - http://www.scopus.com/inward/record.url?scp=84884361151&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84884361151&partnerID=8YFLogxK
U2 - 10.3233/THC-130736
DO - 10.3233/THC-130736
M3 - Article
C2 - 23949178
AN - SCOPUS:84884361151
SN - 0928-7329
VL - 21
SP - 357
EP - 367
JO - Technology and Health Care
JF - Technology and Health Care
IS - 4
ER -