T1 - Corrosion behavior of Zr65Al7.5Ni10Cu17.5 Amorphous alloy for biomedical use
AU - Hiromoto, S.
AU - An Pang Tsai, Pang Tsai
AU - Sumita, M.
AU - Hanawa, T.
PY - 2001
Y1 - 2001
N2 - To evaluate the performance of Zr65Al7.5Ni10Cu17.5 amorphous alloy for the biomedical use, the effects of chloride ion, Cl-, pH, and dissolved oxygen, DO, on the anodic polarization behavior of the alloy were examined in phosphate buffered solutions. Polarization resistance, Rp, at open-circuit potential, Eopen, and pitting potential, Epit, were determined from the polarization curve. Compositions of passive film generated in a pH-7.5 solution with various concentrations of DO were characterized with X-ray photoelectron spectroscopy. In the solution with pH 7.5, the Epit decreased with the increase in logarithm of Cl- concentration, [Cl-], and showed the highest value with the same DO concentration, [DO], as that in vivo. The concentrations of hydroxide group, [OH-], and phosphate ions, [HxPO4(3-x)-], in the passive film were changed with various [DO]s, and the Epit decreased with the increase in [OH-] and [HxPO4(3-x)-]. In the solution with pH 2.2, the Epit was higher than the Eopen with and without DO. Therefore, this alloy may be resistant to the pitting corrosion in vivo.
AB - To evaluate the performance of Zr65Al7.5Ni10Cu17.5 amorphous alloy for the biomedical use, the effects of chloride ion, Cl-, pH, and dissolved oxygen, DO, on the anodic polarization behavior of the alloy were examined in phosphate buffered solutions. Polarization resistance, Rp, at open-circuit potential, Eopen, and pitting potential, Epit, were determined from the polarization curve. Compositions of passive film generated in a pH-7.5 solution with various concentrations of DO were characterized with X-ray photoelectron spectroscopy. In the solution with pH 7.5, the Epit decreased with the increase in logarithm of Cl- concentration, [Cl-], and showed the highest value with the same DO concentration, [DO], as that in vivo. The concentrations of hydroxide group, [OH-], and phosphate ions, [HxPO4(3-x)-], in the passive film were changed with various [DO]s, and the Epit decreased with the increase in [OH-] and [HxPO4(3-x)-]. In the solution with pH 2.2, the Epit was higher than the Eopen with and without DO. Therefore, this alloy may be resistant to the pitting corrosion in vivo.
KW - Biomaterials
KW - Chloride ion
KW - Dissolved oxygen
KW - Electrochemical measurement
KW - pH
KW - ZrAlNiCu amorphous alloy
UR - http://www.scopus.com/inward/record.url?scp=0034970083&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034970083&partnerID=8YFLogxK
U2 - 10.2320/matertrans.42.656
DO - 10.2320/matertrans.42.656
M3 - Article
AN - SCOPUS:0034970083
SN - 1345-9678
VL - 42
SP - 656
EP - 659
JO - Materials Transactions
JF - Materials Transactions
IS - 4
ER -