TY - JOUR
T1 - Cross-sectional elasticity imaging of carotid arterial wall in short-axis plane by transcutaneous ultrasound
AU - Nakagawa, Nozomi
AU - Hasegawa, Hideyuki
AU - Kanai, Hiroshi
PY - 2004/5
Y1 - 2004/5
N2 - We have developed the phased tracking method [H. Kanai, M. Sato, Y. Koiwa and N. Chubachi: IEEE Trans. UFFC 43 (1996) 791.] for measuring the minute change in thickness during one heartbeat and the elasticity of the arterial wall with transcutaneous ultrasound. When this method is applied to a plane perpendicular to the axis of the artery (short-axis plane) using a linear-type probe, only an ultrasonic beam which passes through the center of the artery coincides with the direction of the change in thickness. At other beam positions, the wall motion cannot be accurately tracked because the direction of wall expansion slips off the beam. To obtain the cross-sectional image of elasticity in the short-axis plane using transcutaneous ultrasound, in this paper, the directions of ultrasonic beams are designed so that each beam always passes through the center of the artery; thus, they always coincide with the direction of the wall expansion. In basic experiments, the accuracy in elasticity measurement was evaluated using a silicone rubber tube. In in vivo experiments, the minute change in wall thickness was measured along each ultrasonic beam, and the cross-sectional image of elasticity was obtained in the short-axis plane with transcutaneous ultrasound.
AB - We have developed the phased tracking method [H. Kanai, M. Sato, Y. Koiwa and N. Chubachi: IEEE Trans. UFFC 43 (1996) 791.] for measuring the minute change in thickness during one heartbeat and the elasticity of the arterial wall with transcutaneous ultrasound. When this method is applied to a plane perpendicular to the axis of the artery (short-axis plane) using a linear-type probe, only an ultrasonic beam which passes through the center of the artery coincides with the direction of the change in thickness. At other beam positions, the wall motion cannot be accurately tracked because the direction of wall expansion slips off the beam. To obtain the cross-sectional image of elasticity in the short-axis plane using transcutaneous ultrasound, in this paper, the directions of ultrasonic beams are designed so that each beam always passes through the center of the artery; thus, they always coincide with the direction of the wall expansion. In basic experiments, the accuracy in elasticity measurement was evaluated using a silicone rubber tube. In in vivo experiments, the minute change in wall thickness was measured along each ultrasonic beam, and the cross-sectional image of elasticity was obtained in the short-axis plane with transcutaneous ultrasound.
KW - Elasticity of arterial wall
KW - Short-axis plane
KW - Small change in wall thickness
UR - http://www.scopus.com/inward/record.url?scp=3242779308&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=3242779308&partnerID=8YFLogxK
U2 - 10.1143/JJAP.43.3220
DO - 10.1143/JJAP.43.3220
M3 - Article
AN - SCOPUS:3242779308
SN - 0021-4922
VL - 43
SP - 3220
EP - 3226
JO - Japanese Journal of Applied Physics
JF - Japanese Journal of Applied Physics
IS - 5 B
ER -