Abstract
Current distribution on a 2-layer PCB with lumped circuits is estimated by measuring the near electric field. In this method, the current estimation model is made without considering the electrical parameters of lumped circuits. Experimental results are demonstrated and compared with the numerical results, confirming the validity of this method.
Original language | English |
---|---|
Pages (from-to) | 3788-3791 |
Number of pages | 4 |
Journal | IEICE Transactions on Communications |
Volume | E91-B |
Issue number | 11 |
DOIs | |
Publication status | Published - 2008 |
Keywords
- Current distribution
- Lumped circuit
- Measurement
- Near-field
- PCB