This research was funded by a Grant-in-Aid for JSPS Fellows Grant No. 17J03340 “Establishment of Damage Control Design for Braced Steel Structures Considering Axial Forces Act on Beams” (Principal Investigator: Atsushi Suzuki) and a Grant from The Japan Iron and Steel Federation (Principal Investigator: Atsushi Suzuki). The experiments were supported by Dr. Sachi Furukawa and Kanako Abe. We extend our deepest gratitude for their sincere cooperation.
Publisher Copyright:
© 2019 American Society of Civil Engineers.
PY - 2019/4/1
Y1 - 2019/4/1
N2 - In the design of steel structures, composite effects of stud shear connectors are generally measured using ordinary push-out tests. Furthermore, based on those results, the evaluation formulas of the ultimate shear strength are given in design guidelines. However, a concrete slab is subjected to reversed stress during an earthquake, whereas existing tests consider only compressive stresses on concrete. The mechanical behavior in existing structures thereby might be different from that under compressive force alone. This research proposes a component model of a composite beam modeling the stress in actual buildings. Furthermore, cyclic loading tests were conducted on 14 specimens with different specifications of the stud shear connector, concrete, and rebar. The results showed that the ultimate shear strength is considerably lower than that under compressive stress. Consequently, this paper presents equations to assess structural performance precisely considering various influential factors of composite structures.
AB - In the design of steel structures, composite effects of stud shear connectors are generally measured using ordinary push-out tests. Furthermore, based on those results, the evaluation formulas of the ultimate shear strength are given in design guidelines. However, a concrete slab is subjected to reversed stress during an earthquake, whereas existing tests consider only compressive stresses on concrete. The mechanical behavior in existing structures thereby might be different from that under compressive force alone. This research proposes a component model of a composite beam modeling the stress in actual buildings. Furthermore, cyclic loading tests were conducted on 14 specimens with different specifications of the stud shear connector, concrete, and rebar. The results showed that the ultimate shear strength is considerably lower than that under compressive stress. Consequently, this paper presents equations to assess structural performance precisely considering various influential factors of composite structures.
KW - Composite beam
KW - Concrete slab
KW - Cyclic loading test
KW - Headed stud
KW - Ultimate shear strength
UR - http://www.scopus.com/inward/record.url?scp=85061646511&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85061646511&partnerID=8YFLogxK
U2 - 10.1061/(ASCE)ST.1943-541X.0002294
DO - 10.1061/(ASCE)ST.1943-541X.0002294
M3 - Article
AN - SCOPUS:85061646511
SN - 0733-9445
VL - 145
JO - Journal of Structural Engineering
JF - Journal of Structural Engineering
IS - 4
M1 - 04019015
ER -