Abstract
Cloth step-up transformers are discussed. Magnetic flux density distribution in a magnetic core of a cloth transformer was calculated utilizing magnetic circuit analysis. Optimum winding patterns for maximizing coupling factors or voltage ratios at no-load and the relation of those to the shape of the magnetic flux distribution were found. Step-up voltage ratio of 19 was obtained experimentally.
Original language | English |
---|---|
Pages (from-to) | 2265-2267 |
Number of pages | 3 |
Journal | IEEE Transactions on Magnetics |
Volume | 26 |
Issue number | 5 |
DOIs | |
Publication status | Published - 1990 Sept |
ASJC Scopus subject areas
- Electronic, Optical and Magnetic Materials
- Electrical and Electronic Engineering