Abstract
This work reports a novel approach employing a retarding field analyzer (RFA) to simultaneously measure parallel and perpendicular ion temperatures. I-V curves obtained by the RFA were analyzed considering the influence of selective ion transmission, and the ion temperatures were evaluated. The RFA analysis yielded parallel and perpendicular ion temperatures of 1:2 eV and 2:1 eV, respectively. The perpendicular ion temperature obtained by an ion sensitive probe was 2:0 eV, demonstrating good agreement with that evaluated by the RFA.
Original language | English |
---|---|
Article number | 1201021 |
Journal | Plasma and Fusion Research |
Volume | 19 |
DOIs | |
Publication status | Published - 2024 |
Keywords
- DT-ALPHA
- ion temperature
- radio-frequency plasma
- retarding field analyzer