T1 - Development of a novel centrifugal pump
T2 - Magnetic rotary pump
AU - Naganuma, Shigeru
AU - Yambe, Tomoyuki
AU - Sonobe, Taro
AU - Kobayashi, Shin Ichi
AU - Nitta, Shin Ichi
PY - 1997
Y1 - 1997
N2 - The rotational axis of the centrifugal pump has some associated problems such as blood destruction and sealing between the axis and pump housing. To improve upon these deficits we have developed a new type of blood pump, the magnetic rotary pump (MRP). The MRP has an original design with no rotational axis and no impellers. We made a prototype MRP and examined its hemodynamics in mock circulation. The prototype MRP flow rate is only 1.0 L/min with an afterload of 30 mm Hg, and we have made some modifications in the size and drive mechanisms from these results. The modified MRP can achieve high flow rates and rotational speeds (6.0 L/min with an afterload of 100 mm Hg, 2,000 rpm) in a mock circuit, and the modified MRP was used for left heart assistance in an acute animal experiment. The MRP could maintain the hemodynamics of an anesthetized adult goal. These results suggest that the MRP needs to be improved in several areas, but the MRP may be useful as a blood pump.
AB - The rotational axis of the centrifugal pump has some associated problems such as blood destruction and sealing between the axis and pump housing. To improve upon these deficits we have developed a new type of blood pump, the magnetic rotary pump (MRP). The MRP has an original design with no rotational axis and no impellers. We made a prototype MRP and examined its hemodynamics in mock circulation. The prototype MRP flow rate is only 1.0 L/min with an afterload of 30 mm Hg, and we have made some modifications in the size and drive mechanisms from these results. The modified MRP can achieve high flow rates and rotational speeds (6.0 L/min with an afterload of 100 mm Hg, 2,000 rpm) in a mock circuit, and the modified MRP was used for left heart assistance in an acute animal experiment. The MRP could maintain the hemodynamics of an anesthetized adult goal. These results suggest that the MRP needs to be improved in several areas, but the MRP may be useful as a blood pump.
KW - Linear motor drive
KW - Magnetic rotary pump
KW - New centrifugal pump
UR - http://www.scopus.com/inward/record.url?scp=0030793187&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030793187&partnerID=8YFLogxK
U2 - 10.1111/j.1525-1594.1997.tb03734.x
DO - 10.1111/j.1525-1594.1997.tb03734.x
M3 - Review article
C2 - 9212950
AN - SCOPUS:0030793187
SN - 0160-564X
VL - 21
SP - 746
EP - 750
JO - Artificial Organs
JF - Artificial Organs
IS - 7
ER -