TY - JOUR
T1 - Development of total artificial heart with economical and durability advantages
AU - Yambe, T.
AU - Fukutome, A.
AU - Kobayashi, S.
AU - Nanka, S.
AU - Yoshizawa, M.
AU - Tabayashi, K.
AU - Takeda, H.
AU - Nitta, S.
PY - 1998/5
Y1 - 1998/5
N2 - To develop a total artificial heart (TAH) pump system, we created a design paying particular attention to durability and cost. We adopted a pneumatically driven sac type artificial heart, where the configuration of the sac was decided according to the methodology of flow visualization. Its configuration is almost round to achieve as little stagnation as possible and a low turbulent flow. The main body of the sac was made using polyvinyl chloride (PVC) paste. The paste was poured into an external mold, and heated in a hot air drying oven. Coating was performed using polyurethane. The basic performance of this pump system was tested using a model circulation circuit, and a fitting study through acute animal experiment, using a healthy adult goat, was carried out. As for the TAH produced experimentally, a pump output exceeding 5.0 l/min in the model circulation circuit was provided. Implantation in the internal pleural cavity of a healthy adult goat, 55 kg in weight, proved possible and quite easy in comparison. It is thought that a more refined design in the connector part is desirable. Furthermore, a chronic experiment with the TAH will be carried out, and examination will need to be repeated in the future.
AB - To develop a total artificial heart (TAH) pump system, we created a design paying particular attention to durability and cost. We adopted a pneumatically driven sac type artificial heart, where the configuration of the sac was decided according to the methodology of flow visualization. Its configuration is almost round to achieve as little stagnation as possible and a low turbulent flow. The main body of the sac was made using polyvinyl chloride (PVC) paste. The paste was poured into an external mold, and heated in a hot air drying oven. Coating was performed using polyurethane. The basic performance of this pump system was tested using a model circulation circuit, and a fitting study through acute animal experiment, using a healthy adult goat, was carried out. As for the TAH produced experimentally, a pump output exceeding 5.0 l/min in the model circulation circuit was provided. Implantation in the internal pleural cavity of a healthy adult goat, 55 kg in weight, proved possible and quite easy in comparison. It is thought that a more refined design in the connector part is desirable. Furthermore, a chronic experiment with the TAH will be carried out, and examination will need to be repeated in the future.
KW - Economy
KW - Flow visualization
KW - Pneumatically driven
KW - Silicone ball valve
KW - Total artificial heart
UR - http://www.scopus.com/inward/record.url?scp=0031831821&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031831821&partnerID=8YFLogxK
U2 - 10.1177/039139889802100512
DO - 10.1177/039139889802100512
M3 - Article
C2 - 9684910
AN - SCOPUS:0031831821
SN - 0391-3988
VL - 21
SP - 279
EP - 284
JO - International Journal of Artificial Organs
JF - International Journal of Artificial Organs
IS - 5
ER -