TY - JOUR
T1 - Diagnostic results before and after introduction of autofluorescence bronchoscopy in patients suspected of having lung cancer detected by sputum cytology in lung cancer mass screening
AU - Sato, Masami
AU - Sakurada, Akira
AU - Sagawa, Motoyasu
AU - Minowa, Muneo
AU - Takahashi, Hiroto
AU - Oyaizu, Takeshi
AU - Okada, Yoshinori
AU - Matsumura, Yuji
AU - Tanita, Tatsuo
AU - Kondo, Takashi
N1 - Funding Information:
We wish to thank Professor Stephan Lam for our initial experiences with the LIFE-Lung System. We also thank Professor Manabu Fukumoto and Professor Toru Takahashi, Department of Pathology of our Institute, for diagnosis of the specimens. This study was partly supported by grants-in-aid from the Ministry of Education, Science, Sports and Culture of the Japanese Government.
PY - 2001/6
Y1 - 2001/6
N2 - For the purpose of early detection, we have conducted population-based mass screening for lung cancer by sputum cytology since 1982. Although detection of lung cancer in its early stage is important for a good prognosis, it is often difficult to localize lesions in roentgenographically occult cancer. To clarify the role of autofluorescence bronchoscopy in localizing tumors in patients with roentgenographically occult cancer, we analyzed our diagnostic results. Fifty patients who had been detected by sputum cytology were screened by the light-induced fluorescence endoscope (LIFE)-Lung System from November 1997 to April 1999. We compared the results according to the screening methods: conventional bronchoscopy alone versus LIFE with conventional white-light bronchoscopy (November 1997 to April 1999). Twenty-eight cancerous lesions and 39 borderline lesions were detected by LIFE. Of the 39 borderline lesions, nine were detected only by LIFE. Multicentric lesions including cancer or dysplasia were also detected in 21 of the 50 patients by LIFE. The sensitivity by white-light bronchoscopy alone was 85.3%, whereas that of the LIFE-Lung System with white-light bronchoscopy was 94.1% (P=0.078). There were no cancerous lesions in the area observed as normal by LIFE. We also compared the diagnostic results of two localization methods: brushing of all bronchi (September 1986 to December 1990) and the LIFE-Lung System (November 1997 to April 1999). Although this was a historical comparison, the number of detected borderline lesions increased, which led to a high detection rate in patients with suspected-positive sputum (P=0.0006) by the LIFE-Lung System. In conclusion, the LIFE-Lung System is a safe and non-invasive system for detecting small intraepithelial lesions of the tracheobronchial tree. Autofluorescence bronchoscopy is more efficacious for localizing intraepithelial lesions and places fewer burdens on the patient than brushing of all bronchi.
AB - For the purpose of early detection, we have conducted population-based mass screening for lung cancer by sputum cytology since 1982. Although detection of lung cancer in its early stage is important for a good prognosis, it is often difficult to localize lesions in roentgenographically occult cancer. To clarify the role of autofluorescence bronchoscopy in localizing tumors in patients with roentgenographically occult cancer, we analyzed our diagnostic results. Fifty patients who had been detected by sputum cytology were screened by the light-induced fluorescence endoscope (LIFE)-Lung System from November 1997 to April 1999. We compared the results according to the screening methods: conventional bronchoscopy alone versus LIFE with conventional white-light bronchoscopy (November 1997 to April 1999). Twenty-eight cancerous lesions and 39 borderline lesions were detected by LIFE. Of the 39 borderline lesions, nine were detected only by LIFE. Multicentric lesions including cancer or dysplasia were also detected in 21 of the 50 patients by LIFE. The sensitivity by white-light bronchoscopy alone was 85.3%, whereas that of the LIFE-Lung System with white-light bronchoscopy was 94.1% (P=0.078). There were no cancerous lesions in the area observed as normal by LIFE. We also compared the diagnostic results of two localization methods: brushing of all bronchi (September 1986 to December 1990) and the LIFE-Lung System (November 1997 to April 1999). Although this was a historical comparison, the number of detected borderline lesions increased, which led to a high detection rate in patients with suspected-positive sputum (P=0.0006) by the LIFE-Lung System. In conclusion, the LIFE-Lung System is a safe and non-invasive system for detecting small intraepithelial lesions of the tracheobronchial tree. Autofluorescence bronchoscopy is more efficacious for localizing intraepithelial lesions and places fewer burdens on the patient than brushing of all bronchi.
KW - Autofluorescence bronchoscopy
KW - Brushing of all bronchi
KW - Early detection
KW - Mass screening
KW - Sputum cytology
KW - Tumor localization
UR - http://www.scopus.com/inward/record.url?scp=0035018785&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0035018785&partnerID=8YFLogxK
U2 - 10.1016/S0169-5002(00)00229-4
DO - 10.1016/S0169-5002(00)00229-4
M3 - Article
C2 - 11390006
AN - SCOPUS:0035018785
SN - 0169-5002
VL - 32
SP - 247
EP - 253
JO - Lung Cancer
JF - Lung Cancer
IS - 3
ER -