TY - JOUR
T1 - Difference in water accumulation patterns between solid and closed hollow obturators under a thermal cycle
AU - Tsuboi, Akito
AU - Sakurai, Takeshi
AU - Watanabe, Makoto
PY - 2012/9/1
Y1 - 2012/9/1
N2 - Water accumulation in the hollow space of a maxillary obturator is a continuing problem, and it is unclear whether the porosity of acrylic resin is involved in the mechanism. The purposes of the study were to evaluate the effect of a hollow space in the resin obturator on water sorption under a thermal cycle and to determine factors associated with water accumulation in the obturator. Twenty solid spheres (30-mm diameter) and 40 hemispheres (30-mm diameter, 1.5 mm thickness) were fabricated from heat-polymerized acrylic resin. Closed hollow specimens consisted of 2 hemispheres joined with autopolymerizing resin. Ten solid and 10 closed hollow specimens were immersed in distilled water, whereas the other specimens were stored at 100% relative humidity. Each specimen was thermocycled (5°CY37°C) with a dwell time of 12 hours and weighed every 12 hours for 180 days. Of the 20 closed hollow specimens, 16 showed no water accumulation (8 in distilled water, 8 at 100% humidity). The weight of these specimens became saturated by day 90, with increases fromthe initialweight of 1.41%at 5°Cand 1.36%at 37°C. By day 180, the weights of the solid specimens had increased by 0.96% at 5°C and 0.94% at 37°C. Weight fluctuation associated with temperature was observed for both types of specimens and for all storage conditions. It is concluded that water accumulation inside a closed hollow obturator is not directly related to thewater absorption properties of the acrylic resin but is related to thermal damage of the obturator.
AB - Water accumulation in the hollow space of a maxillary obturator is a continuing problem, and it is unclear whether the porosity of acrylic resin is involved in the mechanism. The purposes of the study were to evaluate the effect of a hollow space in the resin obturator on water sorption under a thermal cycle and to determine factors associated with water accumulation in the obturator. Twenty solid spheres (30-mm diameter) and 40 hemispheres (30-mm diameter, 1.5 mm thickness) were fabricated from heat-polymerized acrylic resin. Closed hollow specimens consisted of 2 hemispheres joined with autopolymerizing resin. Ten solid and 10 closed hollow specimens were immersed in distilled water, whereas the other specimens were stored at 100% relative humidity. Each specimen was thermocycled (5°CY37°C) with a dwell time of 12 hours and weighed every 12 hours for 180 days. Of the 20 closed hollow specimens, 16 showed no water accumulation (8 in distilled water, 8 at 100% humidity). The weight of these specimens became saturated by day 90, with increases fromthe initialweight of 1.41%at 5°Cand 1.36%at 37°C. By day 180, the weights of the solid specimens had increased by 0.96% at 5°C and 0.94% at 37°C. Weight fluctuation associated with temperature was observed for both types of specimens and for all storage conditions. It is concluded that water accumulation inside a closed hollow obturator is not directly related to thewater absorption properties of the acrylic resin but is related to thermal damage of the obturator.
KW - Hollow obturator
KW - PMMA resin
KW - Thermal cycle
KW - Water accumulation
UR - http://www.scopus.com/inward/record.url?scp=84867755289&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84867755289&partnerID=8YFLogxK
U2 - 10.1097/SCS.0b013e318260eeb6
DO - 10.1097/SCS.0b013e318260eeb6
M3 - Article
C2 - 22976652
AN - SCOPUS:84867755289
SN - 1049-2275
VL - 23
SP - 1535
EP - 1539
JO - Journal of Craniofacial Surgery
JF - Journal of Craniofacial Surgery
IS - 5
ER -