Drain output volume after pancreaticoduodenectomy is a useful warning sign for postoperative complications

Taro Fukui, Hiroshi Noda, Fumiaki Watanabe, Takaharu Kato, Yuhei Endo, Hidetoshi Aizawa, Nao Kakizawa, Masahiro Iseki, Toshiki Rikiyama

Research output: Contribution to journalArticlepeer-review

6 Citations (Scopus)

Abstract

Introduction: The drain output volume (DOV) after pancreaticoduodenectomy (PD) is an easily assessable indicator in clinical settings. We explored the utility of the DOV as a possible warning sign of complications after PD. Methods: A total of 404 patients undergoing PD were considered for inclusion. The predictability of the DOV for overall morbidity, major complications, intraabdominal infection (IAI), clinically relevant (CR) postoperative pancreatic fistula (POPF), CR delayed gastric emptying (DGE), CR chyle leak (CL), and CR post-pancreatectomy hemorrhaging (PPH) was evaluated. Results: One hundred (24.8%) patients developed major complications, and 131 (32.4%) developed IAI. Regarding CR post-pancreatectomy complications, 75 (18.6%) patients developed CR-POPF, 23 (5.7%) developed CR-DGE, 20 (5.0%) developed CR-CL, and 28 (6.9%) developed CR-PPH. The median DOV on postoperative day (POD) 1 and POD 3 was 266 and 234.5 ml, respectively. A low DOV on POD 1 was an independent predictor of CR-POPF, and a high DOV on POD 3 was an independent predictor of CR-CL. A receiver operating characteristics (ROC) analysis revealed that the DOV on POD 1 had a negative predictive value (area under the curve [AUC] 0.655, sensitivity 65.0%, specificity 65.3%, 95% confidence interval [CI]: 0.587–0.724), with a calculated optimal cut-off value of 227 ml. An ROC analysis also revealed that the DOV on POD 3 had a positive predictive value (AUC 0.753, sensitivity 70.1%, specificity 75.0%, 95% CI: 0.651–0.856), with a calculated optimal cut-off value of 332 ml. Conclusion: A low DOV on POD 1 might be a postoperative warning sign for CR-POPF, similar to high drain amylase (DA) on POD 1, high DA on POD 3, and high CRP on POD 3. When the DOV on POD 1 after PD was low, surgeons should evaluate the reasons of a low DOV. A high DOV on POD 3 was a postoperative warning sign CR-CL, and might require an appropriate management of protein loss.

Original languageEnglish
Article number279
JournalBMC Surgery
Volume21
Issue number1
DOIs
Publication statusPublished - 2021 Dec
Externally publishedYes

Keywords

  • Chyle leak
  • Drain output
  • Pancreatic fistula
  • Pancreaticoduodenectomy

ASJC Scopus subject areas

  • Surgery

Fingerprint

Dive into the research topics of 'Drain output volume after pancreaticoduodenectomy is a useful warning sign for postoperative complications'. Together they form a unique fingerprint.

Cite this