Abstract
Dynamic simulation model of switched reluctance generator (SRG) was presented. The core material of the SRG was non-oriented silicon steel with a thickness of 0.35 mm. The differences between the calculated and measured values were caused by neglecting the iron losses and mechanical losses of SRG.
Original language | English |
---|---|
Pages (from-to) | ER09 |
Journal | Digests of the Intermag Conference |
Publication status | Published - 2003 |
Event | Intermag 2003: International Magnetics Conference - Boston, MA, United States Duration: 2003 Mar 28 → 2003 Apr 3 |