TY - JOUR
T1 - Effects of diameter of optical absorber visualized by an annular array AR-PAM system on spectrum characteristics of photoacoustic signals
AU - Suzuki, Riku
AU - Sulistyawan, I. Gede Eka
AU - Ishii, Takuro
AU - Saijo, Yoshifumi
N1 - Publisher Copyright:
© 2024 The Japan Society of Applied Physics
PY - 2024/4/1
Y1 - 2024/4/1
N2 - Spectrum characteristics of photoacoustic signals are potential indicators to assess the structural information of optical absorbers. This study investigated whether a spectrum analysis approach can evaluate microvascular diameters obtained by an annular array AR-PAM system. First, 2D numerical simulations were performed to estimate spectral changes in five absorbers with different diameters from 30 to 200 μm. Slope and intercept values from the regression line of the spectrum curve were calculated. Second, the estimated changes were validated by acquiring photoacoustic signals from tungsten wires with five different diameters. Both in numerically and experimentally, spectrum analysis showed the larger the diameter, the greater the lower frequency components, resulting in steeper slope and greater intercept values. Finally, photoacoustic signals acquired from cutaneous microvessels were analyzed. The FWHM diameter of the vessels were corresponded to the slope (r = −0.595; p < 0.05) and intercept (r = 0.657; p < 0.05) values, respectively.
AB - Spectrum characteristics of photoacoustic signals are potential indicators to assess the structural information of optical absorbers. This study investigated whether a spectrum analysis approach can evaluate microvascular diameters obtained by an annular array AR-PAM system. First, 2D numerical simulations were performed to estimate spectral changes in five absorbers with different diameters from 30 to 200 μm. Slope and intercept values from the regression line of the spectrum curve were calculated. Second, the estimated changes were validated by acquiring photoacoustic signals from tungsten wires with five different diameters. Both in numerically and experimentally, spectrum analysis showed the larger the diameter, the greater the lower frequency components, resulting in steeper slope and greater intercept values. Finally, photoacoustic signals acquired from cutaneous microvessels were analyzed. The FWHM diameter of the vessels were corresponded to the slope (r = −0.595; p < 0.05) and intercept (r = 0.657; p < 0.05) values, respectively.
KW - annular array transducer
KW - microvascular imaging
KW - photoacoustic microscopy
KW - spectrum analysis
KW - vector coherence factor
UR - http://www.scopus.com/inward/record.url?scp=85190591057&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85190591057&partnerID=8YFLogxK
U2 - 10.35848/1347-4065/ad3650
DO - 10.35848/1347-4065/ad3650
M3 - Article
AN - SCOPUS:85190591057
SN - 0021-4922
VL - 63
JO - Japanese Journal of Applied Physics
JF - Japanese Journal of Applied Physics
IS - 4
M1 - 04SP57
ER -