TY - JOUR
T1 - Effects of mechanical properties of thermoplastic materials on the initial force of thermoplastic appliances
AU - Kohda, Naohisa
AU - Iijima, Masahiro
AU - Muguruma, Takeshi
AU - Brantley, William A.
AU - Ahluwalia, Karamdeep S.
AU - Mizoguchi, Itaru
PY - 2013/5
Y1 - 2013/5
N2 - Objective: To measure the forces delivered by thermoplastic appliances made from three materials and investigate effects of mechanical properties, material thickness, and amount of activation on orthodontic forces. Materials and Methods: Three thermoplastic materials, Duran (Scheu Dental), Erkodur (Erkodent Erich Kopp GmbH), and Hardcast (Scheu Dental), with two different thicknesses were selected. Values of elastic modulus and hardness were obtained from nanoindentation measurements at 28uC. A custom-fabricated system with a force sensor was employed to obtain measurements of in vitro force delivered by the thermoplastic appliances for 0.5-mm and 1.0-mm activation for bodily tooth movement. Experimental results were subjected to several statistical analyses. Results: Hardcast had significantly lower elastic modulus and hardness than Duran and Erkodur, whose properties were not significantly different. Appliances fabricated from thicker material (0.75 mm or 0.8 mm) always produced significantly greater force than those fabricated from thinner material (0.4 mm or 0.5 mm). Appliances with 1.0-mm activation produced significantly lower force than those with 0.5-mm activation, except for 0.4-mm thick Hardcast appliances. A strong correlation was found between mechanical properties of the thermoplastic materials and force produced by the appliances. Conclusions: Orthodontic forces delivered by thermoplastic appliances depend on the material, thickness, and amount of activation. Mechanical properties of the polymers obtained by nanoindentation testing are predictive of force delivery by these appliances.
AB - Objective: To measure the forces delivered by thermoplastic appliances made from three materials and investigate effects of mechanical properties, material thickness, and amount of activation on orthodontic forces. Materials and Methods: Three thermoplastic materials, Duran (Scheu Dental), Erkodur (Erkodent Erich Kopp GmbH), and Hardcast (Scheu Dental), with two different thicknesses were selected. Values of elastic modulus and hardness were obtained from nanoindentation measurements at 28uC. A custom-fabricated system with a force sensor was employed to obtain measurements of in vitro force delivered by the thermoplastic appliances for 0.5-mm and 1.0-mm activation for bodily tooth movement. Experimental results were subjected to several statistical analyses. Results: Hardcast had significantly lower elastic modulus and hardness than Duran and Erkodur, whose properties were not significantly different. Appliances fabricated from thicker material (0.75 mm or 0.8 mm) always produced significantly greater force than those fabricated from thinner material (0.4 mm or 0.5 mm). Appliances with 1.0-mm activation produced significantly lower force than those with 0.5-mm activation, except for 0.4-mm thick Hardcast appliances. A strong correlation was found between mechanical properties of the thermoplastic materials and force produced by the appliances. Conclusions: Orthodontic forces delivered by thermoplastic appliances depend on the material, thickness, and amount of activation. Mechanical properties of the polymers obtained by nanoindentation testing are predictive of force delivery by these appliances.
KW - Esthetic appliances
KW - Nanoindentation testing
KW - Orthodontic force
KW - Polymer mechanical properties
KW - Thermoplastic appliances
UR - http://www.scopus.com/inward/record.url?scp=84878100897&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84878100897&partnerID=8YFLogxK
U2 - 10.2319/052512-432.1
DO - 10.2319/052512-432.1
M3 - Article
C2 - 23035832
AN - SCOPUS:84878100897
SN - 0003-3219
VL - 83
SP - 476
EP - 483
JO - Angle Orthodontist
JF - Angle Orthodontist
IS - 3
ER -