Abstract
Anodic polarization tests were performed in 0.9% NaCl and 1% lactic acid solutions to characterize the relationship between the corrosion behavior and the microstructures of cast Ti-Ag (5-40% Ag) alloys. The anodic polarization curves for the Ti-Ag alloys up to 17.5% Ag were similar to those for pure titanium in both solutions. On the other hand, an abrupt increase in the current density was observed for the alloys with more than 20% Ag in the NaCl solution and with more than 27.5% Ag in the lactic acid solution. The microstructures of the corroded alloy surfaces indicated the deterioration of precipitated intermetallic compounds along the grain boundaries. The Ti-Ag alloys up to 17.5% Ag had excellent corrosion resistance similar to that of pure titanium. The alloys with 20-25% Ag may be also used as dental alloys, since they passivated again immediately after preferential dissolution in the NaCl solution.
Original language | English |
---|---|
Pages (from-to) | 516-523 |
Number of pages | 8 |
Journal | Dental materials journal |
Volume | 25 |
Issue number | 3 |
DOIs | |
Publication status | Published - 2006 |
Keywords
- Corrosion
- Microstructure
- Titanium alloys
ASJC Scopus subject areas
- Ceramics and Composites
- Dentistry(all)