TY - JOUR
T1 - Electrochemical Immunoassay with Dual-Signal Amplification for Redox Cycling within a Nanoscale Gap
AU - Ito, Kentaro
AU - Y. Inoue, Kumi
AU - Ito-Sasaki, Takahiro
AU - Ino, Kosuke
AU - Shiku, Hitoshi
N1 - Funding Information:
This research was supported by a Grant-in-Aid for JSPS Fellows (no. 20J20465) from the Japan Society for the Promotion of Science (JSPS). This research was partially supported by the JST COI (no. JPMJCE1303), from the Japan Science and Technology Agency.
Publisher Copyright:
© 2021 American Chemical Society. All rights reserved.
PY - 2021/11/26
Y1 - 2021/11/26
N2 - Here, we report a highly sensitive and easy-to-use electrochemical immunoassay using a dual-signal amplification strategy of redox cycling within a nanoscale gap and the Limulus amebocyte lysate (LAL) cascade reaction. After the antigen-antibody reaction using an endotoxin-labeled antibody, the LAL reaction was induced by endotoxin as the first signal amplification. Subsequently, p-aminophenol (pAP) liberated from peptide-conjugated pAP (Boc-Leu-Gly-Arg-pAP; LGR-pAP), at the last step of the LAL reaction, was detected with redox cycling within a nanoscale gap using a fabricated device as the second signal amplification. First, an electrochemical immunoassay for goat immunoglobulin G (IgG), used as a model analyte, was performed with an endotoxin-labeled antibody using a 96-well plate. The results indicated that the endotoxin-labeled antibody was usable for immunoassays. However, a high background was observed. To decrease the background and increase the efficiency of the reactions, magnetic beads in an endotoxin-free test tube were used for the immunosorbent assay. After optimization of the condition, goat IgG was successfully detected with single-signal amplification of the cascade reaction at concentrations as low as 10 pg/mL (67 fM) using a Au disc electrode. Finally, an immunoassay for goat IgG on magnetic beads using a redox cycling-inducing device was performed. With the dual-signal amplification strategies of redox cycling within a nanoscale gap and LAL reactions, the detection limit was 70 fg/mL (470 aM). Our highly sensitive and easy-to-use immunoassay strategy provides a platform for clinical diagnosis to detect early-stage infections.
AB - Here, we report a highly sensitive and easy-to-use electrochemical immunoassay using a dual-signal amplification strategy of redox cycling within a nanoscale gap and the Limulus amebocyte lysate (LAL) cascade reaction. After the antigen-antibody reaction using an endotoxin-labeled antibody, the LAL reaction was induced by endotoxin as the first signal amplification. Subsequently, p-aminophenol (pAP) liberated from peptide-conjugated pAP (Boc-Leu-Gly-Arg-pAP; LGR-pAP), at the last step of the LAL reaction, was detected with redox cycling within a nanoscale gap using a fabricated device as the second signal amplification. First, an electrochemical immunoassay for goat immunoglobulin G (IgG), used as a model analyte, was performed with an endotoxin-labeled antibody using a 96-well plate. The results indicated that the endotoxin-labeled antibody was usable for immunoassays. However, a high background was observed. To decrease the background and increase the efficiency of the reactions, magnetic beads in an endotoxin-free test tube were used for the immunosorbent assay. After optimization of the condition, goat IgG was successfully detected with single-signal amplification of the cascade reaction at concentrations as low as 10 pg/mL (67 fM) using a Au disc electrode. Finally, an immunoassay for goat IgG on magnetic beads using a redox cycling-inducing device was performed. With the dual-signal amplification strategies of redox cycling within a nanoscale gap and LAL reactions, the detection limit was 70 fg/mL (470 aM). Our highly sensitive and easy-to-use immunoassay strategy provides a platform for clinical diagnosis to detect early-stage infections.
KW - electrochemical immunosensor
KW - endotoxin
KW - Limulus amebocyte lysate reaction
KW - redox cycling
UR - http://www.scopus.com/inward/record.url?scp=85118598827&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85118598827&partnerID=8YFLogxK
U2 - 10.1021/acsanm.1c02837
DO - 10.1021/acsanm.1c02837
M3 - Article
AN - SCOPUS:85118598827
SN - 2574-0970
VL - 4
SP - 12393
EP - 12400
JO - ACS Applied Nano Materials
JF - ACS Applied Nano Materials
IS - 11
ER -