TY - JOUR
T1 - Electrochemical sensor array and its application to real time imaging of a brain slice
AU - Kasai, Nahoko
AU - Shimada, Akiyoshi
AU - Nyberg, Tobias
AU - Torimitsu, Keiichi
PY - 2007
Y1 - 2007
N2 - An electrochemical sensing system using a planar microelectrode array has been developed to monitor biological molecules with relatively high special and temporal resolutions. This enables us a real time imaging of the biological molecules release from a tissue invasively. In this study, we have established a multichannel hydrogen peroxide (H2O2:) sensing system to monitor the real time H2O2 distribution in a tissue using a planar sensor array. H2O2 has been recognized in association with the pathology of neurological diseases because it is a by-product of a degenerative reaction of reactive oxygen species, one of the major causes of oxidative stress in mammalian cells. The sensor array is based on a 64-channel ITO electrode array of 50×50 um electrodes modified with an enzyme, horseradish peroxidase, and an electron transfer mediator. Then we place a cultured rat hippocampal slice on the array and measure the current at each sensor using a multipotentiostat. When we introduce bicuculline into the solution as a stimulant, in the presence of a catalase inhibitor, we can observe a distinct increase in the H2O2 concentration. This real-time H2O2 distribution monitoring system will be a powerful tool with which to explore the neuronal cell death mechanism in biological systems.
AB - An electrochemical sensing system using a planar microelectrode array has been developed to monitor biological molecules with relatively high special and temporal resolutions. This enables us a real time imaging of the biological molecules release from a tissue invasively. In this study, we have established a multichannel hydrogen peroxide (H2O2:) sensing system to monitor the real time H2O2 distribution in a tissue using a planar sensor array. H2O2 has been recognized in association with the pathology of neurological diseases because it is a by-product of a degenerative reaction of reactive oxygen species, one of the major causes of oxidative stress in mammalian cells. The sensor array is based on a 64-channel ITO electrode array of 50×50 um electrodes modified with an enzyme, horseradish peroxidase, and an electron transfer mediator. Then we place a cultured rat hippocampal slice on the array and measure the current at each sensor using a multipotentiostat. When we introduce bicuculline into the solution as a stimulant, in the presence of a catalase inhibitor, we can observe a distinct increase in the H2O2 concentration. This real-time H2O2 distribution monitoring system will be a powerful tool with which to explore the neuronal cell death mechanism in biological systems.
KW - Electrochemical sensor
KW - Hippocampal slice
KW - Hydrogen peroxide
KW - Microelectrode array
UR - http://www.scopus.com/inward/record.url?scp=33847759036&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33847759036&partnerID=8YFLogxK
U2 - 10.1541/ieejeiss.127.217
DO - 10.1541/ieejeiss.127.217
M3 - Article
AN - SCOPUS:33847759036
SN - 0385-4221
VL - 127
SP - 217
EP - 221
JO - IEEJ Transactions on Electronics, Information and Systems
JF - IEEJ Transactions on Electronics, Information and Systems
IS - 2
ER -