TY - JOUR
T1 - Evaluation of pH at the bacteria-dental cement interface
AU - Mayanagi, G.
AU - Igarashi, K.
AU - Washio, J.
AU - Nakajo, K.
AU - Domon-Tawaraya, H.
AU - Takahashi, N.
N1 - Funding Information:
This study was supported in part by Research and Education Funding for Inter-University Research Project (Highly-functional Interface Science: Innovation of Biomaterials with Highly-Functional Interface to Host and Parasite), MEXT, Japan, and in part by a Grant-in-Aid for Young Scientist B ( 22792104 ) from the Ministry of Education, Culture, Sports, Science and Technology, Japan .
PY - 2011/12
Y1 - 2011/12
N2 - Physiochemical assessment of the parasite-biomaterial interface is essential in the development of new biomaterials. The purpose of this study was to develop a method to evaluate pH at the bacteria-dental cement interface and to demonstrate physiochemical interaction at the interface. The experimental apparatus with a well (4.0 mm in diameter and 2.0 mm deep) was made of polymethyl methacrylate with dental cement or polymethyl methacrylate (control) at the bottom. Three representative dental cements (glass-ionomer, zinc phosphate, and zinc oxide-eugenol cements) were used. Each specimen was immersed in 2 mM potassium phosphate buffer for 10 min, 24 hrs, 1 wk, or 4 wks. The well was packed with Streptococcus mutans NCTC 10449, and a miniature pH electrode was placed at the interface between bacterial cells and dental cement. The pH was monitored after the addition of 1% glucose, and the fluoride contained in the cells was quantified. Glass-ionomer cement inhibited the bacteria-induced pH fall significantly compared with polymethyl methacrylate (control) at the interface (10 min, 5.16 ± 0.19 vs. 4.50 ± 0.07; 24 hrs, 5.20 ± 0.07 vs. 4.59 ± 0.11; 1 wk, 5.34 ± 0.14 vs. 4.57 ± 0.11; and 4 wks, 4.95 ± 0.27 vs. 4.40 ± 0.14), probably due to the fluoride released from the cement. This method could be useful for the assessment of pH at the parasite-biomaterial interface.
AB - Physiochemical assessment of the parasite-biomaterial interface is essential in the development of new biomaterials. The purpose of this study was to develop a method to evaluate pH at the bacteria-dental cement interface and to demonstrate physiochemical interaction at the interface. The experimental apparatus with a well (4.0 mm in diameter and 2.0 mm deep) was made of polymethyl methacrylate with dental cement or polymethyl methacrylate (control) at the bottom. Three representative dental cements (glass-ionomer, zinc phosphate, and zinc oxide-eugenol cements) were used. Each specimen was immersed in 2 mM potassium phosphate buffer for 10 min, 24 hrs, 1 wk, or 4 wks. The well was packed with Streptococcus mutans NCTC 10449, and a miniature pH electrode was placed at the interface between bacterial cells and dental cement. The pH was monitored after the addition of 1% glucose, and the fluoride contained in the cells was quantified. Glass-ionomer cement inhibited the bacteria-induced pH fall significantly compared with polymethyl methacrylate (control) at the interface (10 min, 5.16 ± 0.19 vs. 4.50 ± 0.07; 24 hrs, 5.20 ± 0.07 vs. 4.59 ± 0.11; 1 wk, 5.34 ± 0.14 vs. 4.57 ± 0.11; and 4 wks, 4.95 ± 0.27 vs. 4.40 ± 0.14), probably due to the fluoride released from the cement. This method could be useful for the assessment of pH at the parasite-biomaterial interface.
KW - fluoride
KW - glass-ionomer cement
KW - interface
KW - ISFET pH electrode
KW - pH
KW - Streptococcus
UR - http://www.scopus.com/inward/record.url?scp=81555220946&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=81555220946&partnerID=8YFLogxK
U2 - 10.1177/0022034511423392
DO - 10.1177/0022034511423392
M3 - Article
C2 - 21933936
AN - SCOPUS:81555220946
SN - 0022-0345
VL - 90
SP - 1446
EP - 1450
JO - Journal of Dental Research
JF - Journal of Dental Research
IS - 12