Evaluation of resistance and inductance of loose connector contact

Kazuya Uehara, Yu Ichi Hayashi, Takaaki Mizuki, Hideaki Sone

Research output: Contribution to journalArticlepeer-review

4 Citations (Scopus)

Abstract

The contact surface of a loose connector has both contact resistance and low inductance, and the inductance depends on the distribution of the true contacts. The contact resistance and inductance were measured by time-domain reflectometry (TDR) for seven contact distribution models. The resistance was approximately constant, while the maximum inductance varied more than twofold depending on the distribution model.

Original languageEnglish
Pages (from-to)1148-1150
Number of pages3
JournalIEICE Transactions on Electronics
VolumeE96-C
Issue number9
DOIs
Publication statusPublished - 2013 Sept

Keywords

  • Loose contact
  • TDR
  • True contact

Fingerprint

Dive into the research topics of 'Evaluation of resistance and inductance of loose connector contact'. Together they form a unique fingerprint.