N2 - The fall rates of the current types of expendable conductivity-temperature-depth (XCTD) profilers and one under development are evaluated based on a series of co-located measurements with conventional conductivity-temperature-depth (CTD) profilers in the North Pacific. The types of probes investigated are the XCTD-1, the XCTD-2, the XCTD-3, and the XCTD-5 manufactured by Tsurumi Seiki Co., Ltd. It is confirmed that the present manufacturer's fall-rate coefficients for the XCTD-1/2 satisfy the accuracy guarantee of 2% of depth, at depth greater than 20 m. The coefficients of all XCTD types tested are dependent on water temperature, and the probes tend to fall slightly faster in warmer water. New sets of coefficients are given for the individual types, in a form that includes a correction for water temperature. It is also found that the ring hood structure of the XCTD-1/2 is effective in stabilizing the fall rates. The newer XCTD-3/5, which lack the hood, show larger scatter in the fall rate and occasionally violates the guaranteed depth accuracy.
AB - The fall rates of the current types of expendable conductivity-temperature-depth (XCTD) profilers and one under development are evaluated based on a series of co-located measurements with conventional conductivity-temperature-depth (CTD) profilers in the North Pacific. The types of probes investigated are the XCTD-1, the XCTD-2, the XCTD-3, and the XCTD-5 manufactured by Tsurumi Seiki Co., Ltd. It is confirmed that the present manufacturer's fall-rate coefficients for the XCTD-1/2 satisfy the accuracy guarantee of 2% of depth, at depth greater than 20 m. The coefficients of all XCTD types tested are dependent on water temperature, and the probes tend to fall slightly faster in warmer water. New sets of coefficients are given for the individual types, in a form that includes a correction for water temperature. It is also found that the ring hood structure of the XCTD-1/2 is effective in stabilizing the fall rates. The newer XCTD-3/5, which lack the hood, show larger scatter in the fall rate and occasionally violates the guaranteed depth accuracy.
KW - Expendable conductivity-temperature-depth profiler
KW - Fall-rate equation
KW - Salinity measurement
KW - Temperature measurement
KW - VOS monitoring
KW - XCTD
UR - http://www.scopus.com/inward/record.url?scp=41549115012&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=41549115012&partnerID=8YFLogxK
U2 - 10.1016/j.dsr.2007.12.011
DO - 10.1016/j.dsr.2007.12.011
M3 - Article
AN - SCOPUS:41549115012
SN - 0967-0637
VL - 55
SP - 571
EP - 586
JO - Deep-Sea Research Part I: Oceanographic Research Papers
JF - Deep-Sea Research Part I: Oceanographic Research Papers
IS - 4
ER -