TY - JOUR
T1 - First imaging demonstration of a crosshair light-sharing PET detector
AU - Yoshida, Eiji
AU - Akamatsu, Go
AU - Tashima, Hideaki
AU - Kamada, Kei
AU - Yoshikawa, Akira
AU - Yamaya, Taiga
N1 - Publisher Copyright:
© 2021 Institute of Physics and Engineering in Medicine.
PY - 2021/3/21
Y1 - 2021/3/21
N2 - The crosshair light-sharing (CLS) PET detector is our original depth-of-interaction (DOI) detector, which is based on a single-ended readout scheme with quadrisected crystals comparable in size to a photo-sensor. In this work, we developed 32 CLS PET detectors, each of which consisted of a multi-pixel photon counter (MPPC) array and gadolinium fine aluminum garnet (GFAG) crystals, and we developed a benchtop prototype of a small animal size PET. Each GFAG crystal was 1.45 × 1.45 × 15 mm3. The MPPC had a surface area of 3.0 × 3.0 mm2. The benchtop prototype had two detector rings of 16 detector blocks. The ring diameter and axial field-of-view were 14.2 cm and 4.9 cm, respectively. The data acquisition system used was the PETsys silicon photomultiplier readout system. The continuous DOI information was binned into three DOI layers by applying a look-up-table to a 2D position histogram. Also, energy and timing information was corrected using DOI information. After the calibration procedure, the energy resolution and the coincidence time resolution were 14.6% and 531 ps, respectively. Imaging test results of a small rod phantom obtained by an iterative reconstruction method showed clear separation of 1.6 mm rods with the help of DOI information.
AB - The crosshair light-sharing (CLS) PET detector is our original depth-of-interaction (DOI) detector, which is based on a single-ended readout scheme with quadrisected crystals comparable in size to a photo-sensor. In this work, we developed 32 CLS PET detectors, each of which consisted of a multi-pixel photon counter (MPPC) array and gadolinium fine aluminum garnet (GFAG) crystals, and we developed a benchtop prototype of a small animal size PET. Each GFAG crystal was 1.45 × 1.45 × 15 mm3. The MPPC had a surface area of 3.0 × 3.0 mm2. The benchtop prototype had two detector rings of 16 detector blocks. The ring diameter and axial field-of-view were 14.2 cm and 4.9 cm, respectively. The data acquisition system used was the PETsys silicon photomultiplier readout system. The continuous DOI information was binned into three DOI layers by applying a look-up-table to a 2D position histogram. Also, energy and timing information was corrected using DOI information. After the calibration procedure, the energy resolution and the coincidence time resolution were 14.6% and 531 ps, respectively. Imaging test results of a small rod phantom obtained by an iterative reconstruction method showed clear separation of 1.6 mm rods with the help of DOI information.
UR - http://www.scopus.com/inward/record.url?scp=85103498143&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85103498143&partnerID=8YFLogxK
U2 - 10.1088/1361-6560/abe839
DO - 10.1088/1361-6560/abe839
M3 - Article
C2 - 33607635
AN - SCOPUS:85103498143
SN - 0031-9155
VL - 66
JO - Physics in Medicine and Biology
JF - Physics in Medicine and Biology
IS - 6
M1 - 065013
ER -