TY - GEN
T1 - Forward-nulling passive millimeter wave imaging using cooling water-wall
AU - Sato, Hiroyasu
AU - Sawaya, Kunio
PY - 2013
Y1 - 2013
N2 - A cooling water-wall room is developed and the forward-nulling passive millimeter-wave (PMMW) imaging is performed using developed room. It is shown experimentally that high-quality of PMMW images is obtained by the presence of the cooling water-wall room which works as a nulling source and a shielding wall.
AB - A cooling water-wall room is developed and the forward-nulling passive millimeter-wave (PMMW) imaging is performed using developed room. It is shown experimentally that high-quality of PMMW images is obtained by the presence of the cooling water-wall room which works as a nulling source and a shielding wall.
UR - http://www.scopus.com/inward/record.url?scp=84894135765&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84894135765&partnerID=8YFLogxK
U2 - 10.1109/APS.2013.6711064
DO - 10.1109/APS.2013.6711064
M3 - Conference contribution
AN - SCOPUS:84894135765
SN - 9781467353175
T3 - IEEE Antennas and Propagation Society, AP-S International Symposium (Digest)
SP - 810
EP - 811
BT - 2013 IEEE Antennas and Propagation Society International Symposium, APSURSI 2013 - Proceedings
T2 - 2013 IEEE Antennas and Propagation Society International Symposium, APSURSI 2013
Y2 - 7 July 2013 through 13 July 2013
ER -