TY - JOUR
T1 - Hemolysis and von Willebrand factor degradation in mechanical shuttle shear flow tester
AU - Shiraishi, Yasuyuki
AU - Tachizaki, Yuma
AU - Inoue, Yusuke
AU - Hayakawa, Masaki
AU - Yamada, Akihiro
AU - Kayashima, Michinori
AU - Matsumoto, Masanori
AU - Horiuchi, Hisanori
AU - Yambe, Tomoyuki
N1 - Funding Information:
This research was supported by JSPS Kakenhi under Grant numbers JP15KK0294 and JP19K12748 and by AMED under Grant number JP19ek019246h0003.
Funding Information:
This research was supported by Kakenhi under Grant numbers JP15KK0294 and JP19K12748 and by AMED under Grant number JP19ek019246h0003.
Publisher Copyright:
© 2021, The Author(s).
PY - 2021/6
Y1 - 2021/6
N2 - Chronic blood trauma caused by the shear stresses generated by mechanical circulatory support (MCS) systems is one of the major concerns to be considered during the development of ventricular assist devices. Large multimers with high-molecular-weight von Willebrand factor (VWF) are extended by the fluid forces in a shear flow and are cleaved by ADAMTS13. Since the mechanical revolving motions in artificial MCSs induce cleavage in large VWF multimers, nonsurgical bleeding associated with the MCS is likely to occur after mechanical hemodynamic support. In this study, the shear stress (~ 600 Pa) and exposure time related to hemolysis and VWF degradation were investigated using a newly designed mechanical shuttle shear flow tester. The device consisted of a pair of cylinders facing the test section of a small-sized pipe; both the cylinders were connected to composite mechanical heads with a sliding-sleeve structure for axial separation during the withdrawing motion. The influence of exposure time, in terms of the number of stress cycles, on hemolysis and VWF degradation was confirmed using fresh goat blood, and the differences in the rates of dissipation of the multimers were established. The plasma-free hemoglobin levels showed a logarithmic increase corresponding to the number of cycles, and the dissipation of large VWF multimers occurred within a few seconds under high shear stress flow conditions.
AB - Chronic blood trauma caused by the shear stresses generated by mechanical circulatory support (MCS) systems is one of the major concerns to be considered during the development of ventricular assist devices. Large multimers with high-molecular-weight von Willebrand factor (VWF) are extended by the fluid forces in a shear flow and are cleaved by ADAMTS13. Since the mechanical revolving motions in artificial MCSs induce cleavage in large VWF multimers, nonsurgical bleeding associated with the MCS is likely to occur after mechanical hemodynamic support. In this study, the shear stress (~ 600 Pa) and exposure time related to hemolysis and VWF degradation were investigated using a newly designed mechanical shuttle shear flow tester. The device consisted of a pair of cylinders facing the test section of a small-sized pipe; both the cylinders were connected to composite mechanical heads with a sliding-sleeve structure for axial separation during the withdrawing motion. The influence of exposure time, in terms of the number of stress cycles, on hemolysis and VWF degradation was confirmed using fresh goat blood, and the differences in the rates of dissipation of the multimers were established. The plasma-free hemoglobin levels showed a logarithmic increase corresponding to the number of cycles, and the dissipation of large VWF multimers occurred within a few seconds under high shear stress flow conditions.
KW - Hemolysis
KW - Large multimer
KW - Shuttle shear flow tester
KW - Von Willebrand factor
UR - http://www.scopus.com/inward/record.url?scp=85100712927&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85100712927&partnerID=8YFLogxK
U2 - 10.1007/s10047-020-01219-3
DO - 10.1007/s10047-020-01219-3
M3 - Article
C2 - 33559766
AN - SCOPUS:85100712927
SN - 1434-7229
VL - 24
SP - 111
EP - 119
JO - Journal of Artificial Organs
JF - Journal of Artificial Organs
IS - 2
ER -