TY - JOUR
T1 - In vitro short-term platelet adhesion on various metals
AU - Tanaka, Yuta
AU - Kurashima, Kazuya
AU - Saito, Haruka
AU - Nagai, Akiko
AU - Tsutsumi, Yusuke
AU - Doi, Hisashi
AU - Nomura, Naoyuki
AU - Hanawa, Takao
PY - 2009/9
Y1 - 2009/9
N2 - The in vitro short-term platelet adhesion on various metals, as accelerated by the addition of Ca2+, was evaluated in this study. Metals used for medical devices [an austenitic stainless steel, a cobalt (Co)-chromium (Cr)-molybdenum (Mo) alloy, a titanium (Ti)-6 aluminum (Al)-4 vanadium (V) alloy, a Ti-6Al-7 niobium (Nb) alloy, a Tinickel (Ni) alloy, and commercially pure Ti] were immersed into a platelet-rich plasma solution for 5 or 20 min, and platelet adhesion and aggregation on the surfaces were observed using a scanning electron microscope. The platelet adhesion level on each metal after 5 min of immersion in a platelet-rich plasma solution was the smallest in this order: Stainless steel ≤ Co-Cr-Mo alloy < Ti-6Al-4V alloy < Ti-6Al-7Nb alloy < Ti-Ni alloy = Ti. The levels after 5 min of immersion were almost the same as those after 20 min of immersion. Platelet adhesion was minimal on stainless steel and Co-Cr-Mo alloy, which have a Cr2O 3-containing passive surface oxide film, but was accelerated on Ti and Ti alloys having a TiO2-contanining film. A Cr2O 3-containing oxide film has a lower relative permittivity than a TiO2-contanining film; it thus supports a larger electrostatic force than the latter, adsorbs more albumins, which work as inhibitory proteins, and inhibits platelet aggregation. Therefore, platelet adhesion and aggregation are controlled by the composition of the surface oxide film on a metal due to the relative permittivity of the metal, which influences the amount of adsorbed proteins.
AB - The in vitro short-term platelet adhesion on various metals, as accelerated by the addition of Ca2+, was evaluated in this study. Metals used for medical devices [an austenitic stainless steel, a cobalt (Co)-chromium (Cr)-molybdenum (Mo) alloy, a titanium (Ti)-6 aluminum (Al)-4 vanadium (V) alloy, a Ti-6Al-7 niobium (Nb) alloy, a Tinickel (Ni) alloy, and commercially pure Ti] were immersed into a platelet-rich plasma solution for 5 or 20 min, and platelet adhesion and aggregation on the surfaces were observed using a scanning electron microscope. The platelet adhesion level on each metal after 5 min of immersion in a platelet-rich plasma solution was the smallest in this order: Stainless steel ≤ Co-Cr-Mo alloy < Ti-6Al-4V alloy < Ti-6Al-7Nb alloy < Ti-Ni alloy = Ti. The levels after 5 min of immersion were almost the same as those after 20 min of immersion. Platelet adhesion was minimal on stainless steel and Co-Cr-Mo alloy, which have a Cr2O 3-containing passive surface oxide film, but was accelerated on Ti and Ti alloys having a TiO2-contanining film. A Cr2O 3-containing oxide film has a lower relative permittivity than a TiO2-contanining film; it thus supports a larger electrostatic force than the latter, adsorbs more albumins, which work as inhibitory proteins, and inhibits platelet aggregation. Therefore, platelet adhesion and aggregation are controlled by the composition of the surface oxide film on a metal due to the relative permittivity of the metal, which influences the amount of adsorbed proteins.
KW - Metals
KW - Platelet adhesion
KW - Protein adsorption
KW - Surface oxide film
UR - http://www.scopus.com/inward/record.url?scp=72849138191&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=72849138191&partnerID=8YFLogxK
U2 - 10.1007/s10047-009-0468-1
DO - 10.1007/s10047-009-0468-1
M3 - Article
C2 - 19894092
AN - SCOPUS:72849138191
SN - 1434-7229
VL - 12
SP - 182
EP - 186
JO - Journal of Artificial Organs
JF - Journal of Artificial Organs
IS - 3
ER -