TY - JOUR
T1 - Influence of standardization on the precision (reproducibility) of dental cast analysis with virtual 3-dimensional models
AU - Hayashi, Kazuo
AU - Chung, Onejune
AU - Park, Seojung
AU - Lee, Seung Pyo
AU - Sachdeva, Rohit C.L.
AU - Mizoguchi, Itaru
N1 - Publisher Copyright:
© 2015 American Association of Orthodontists.
PY - 2015/3/1
Y1 - 2015/3/1
N2 - Introduction Virtual 3-dimensional (3D) models obtained by scanning of physical casts have become an alternative to conventional dental cast analysis in orthodontic treatment. If the precision (reproducibility) of virtual 3D model analysis can be further improved, digital orthodontics could be even more widely accepted. The purpose of this study was to clarify the influence of "standardization" of the target points for dental cast analysis using virtual 3D models. Physical plaster models were also measured to obtain additional information. Methods Five sets of dental casts were used. The dental casts were scanned with R700 (3Shape, Copenhagen, Denmark) and REXCAN DS2 3D (Solutionix, Seoul, Korea) scanners. In this study, 3 system and software packages were used: SureSmile (OraMetrix, Richardson, Tex), Rapidform (Inus, Seoul, Korea), and I-DEAS (SDRC, Milford, Conn). Results Without standardization, the maximum differences were observed between the SureSmile software and the Rapidform software (0.39 mm ± 0.07). With standardization, the maximum differences were observed between the SureSmile software and measurements with a digital caliper (0.099 mm ± 0.01), and this difference was significantly greater (P <0.05) than the 2 other mean difference values. Furthermore, the results of this study showed that the mean differences "WITH" standardization were significantly lower than those "WITHOUT" standardization for all systems, software packages, or methods. Conclusions The results showed that elimination of the influence of usability or habituation is important for improving the reproducibility of dental cast analysis.
AB - Introduction Virtual 3-dimensional (3D) models obtained by scanning of physical casts have become an alternative to conventional dental cast analysis in orthodontic treatment. If the precision (reproducibility) of virtual 3D model analysis can be further improved, digital orthodontics could be even more widely accepted. The purpose of this study was to clarify the influence of "standardization" of the target points for dental cast analysis using virtual 3D models. Physical plaster models were also measured to obtain additional information. Methods Five sets of dental casts were used. The dental casts were scanned with R700 (3Shape, Copenhagen, Denmark) and REXCAN DS2 3D (Solutionix, Seoul, Korea) scanners. In this study, 3 system and software packages were used: SureSmile (OraMetrix, Richardson, Tex), Rapidform (Inus, Seoul, Korea), and I-DEAS (SDRC, Milford, Conn). Results Without standardization, the maximum differences were observed between the SureSmile software and the Rapidform software (0.39 mm ± 0.07). With standardization, the maximum differences were observed between the SureSmile software and measurements with a digital caliper (0.099 mm ± 0.01), and this difference was significantly greater (P <0.05) than the 2 other mean difference values. Furthermore, the results of this study showed that the mean differences "WITH" standardization were significantly lower than those "WITHOUT" standardization for all systems, software packages, or methods. Conclusions The results showed that elimination of the influence of usability or habituation is important for improving the reproducibility of dental cast analysis.
UR - http://www.scopus.com/inward/record.url?scp=84923622208&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84923622208&partnerID=8YFLogxK
U2 - 10.1016/j.ajodo.2014.11.015
DO - 10.1016/j.ajodo.2014.11.015
M3 - Article
C2 - 25726405
AN - SCOPUS:84923622208
SN - 0889-5406
VL - 147
SP - 373
EP - 380
JO - American Journal of Orthodontics and Dentofacial Orthopedics
JF - American Journal of Orthodontics and Dentofacial Orthopedics
IS - 3
ER -