Abstract
The electric characteristic of stress corrosion crack (SCC) in eddy current testing (ECT) through analyzing experimental and simulated signals was discussed. Inspection of SCC firstly was carried out. In the following simulation SCC was modeled based on the results of destructive testing. The results show that it is more appropriate to focus on equivalent resistance of SCC in the eddy current simulation. Furthermore considering the distribution of conductivity enables the better reconstruction of SCC.
Original language | English |
---|---|
Pages (from-to) | 625-628 |
Number of pages | 4 |
Journal | Huadong Ligong Daxue Xuebao/Journal of East China University of Science and Technology |
Volume | 39 |
Issue number | 5 |
Publication status | Published - 2013 Oct 1 |
Keywords
- Conductive character
- Eddy current testing
- Nondestructive testing
- Stress corrosion crack
ASJC Scopus subject areas
- Chemical Engineering(all)
- Engineering(all)
- Materials Chemistry