TY - GEN
T1 - Investigation of biocompatibility on nitrogen-doped a-C:H film coating scaffold surface in in-vivo and in-vitro tests
AU - Ohgoe, Yasuharu
AU - Wada, Tomoaki
AU - Shiraishi, Yasuyuki
AU - Miura, Hidekazu
AU - Hirakuri, Kenji K.
AU - Funakubo, Akio
AU - Yambe, Tomoyuki
AU - Fukui, Yasuhiro
PY - 2013
Y1 - 2013
N2 - In this study, in order to investigate biocompatibility of nitrogen-doped hydrogenated amorphous carbon (a-C:H:N) film coating segmented polyurethane (SPU) scaffold fiber sheet (a-C:H:N-Scaffold) in in-vitro test, mouse fibroblasts (NIH 3T3) cells were grown on the a-C:H:N-Scaffold. The cell behavior was monitored by time-lapse imaging system. Additionally, the a-C:H:N-Scaffold was implanted at partial aorta descendens of a goat for 35 days. The surface morphology, composition, and wettability of the a-C:H:N-scaffold was estimated by Scanning Electron Microscope (SEM), X-ray photoelectron spectrometer (XPS), and contact angle measurement. In in-vitro test, it was observed that a-C:H:N film coating had a facilitatory effect on cell motility and cell growth. In in-vivo test, it was observed that the a-C:H:N-Scaffold surface was uniformly covered by neointima. The a-C:H:N-Scaffold surface had no thrombus formation as an inflammatory reaction and it was shown that the a-C:H:N film coating had a good blood compatibility. These results suggest that a-C:H:N film coating has good cytocompatibility and blood compatibility and it is a promising approach for improvement of biocompatibility of biomaterial surfaces.
AB - In this study, in order to investigate biocompatibility of nitrogen-doped hydrogenated amorphous carbon (a-C:H:N) film coating segmented polyurethane (SPU) scaffold fiber sheet (a-C:H:N-Scaffold) in in-vitro test, mouse fibroblasts (NIH 3T3) cells were grown on the a-C:H:N-Scaffold. The cell behavior was monitored by time-lapse imaging system. Additionally, the a-C:H:N-Scaffold was implanted at partial aorta descendens of a goat for 35 days. The surface morphology, composition, and wettability of the a-C:H:N-scaffold was estimated by Scanning Electron Microscope (SEM), X-ray photoelectron spectrometer (XPS), and contact angle measurement. In in-vitro test, it was observed that a-C:H:N film coating had a facilitatory effect on cell motility and cell growth. In in-vivo test, it was observed that the a-C:H:N-Scaffold surface was uniformly covered by neointima. The a-C:H:N-Scaffold surface had no thrombus formation as an inflammatory reaction and it was shown that the a-C:H:N film coating had a good blood compatibility. These results suggest that a-C:H:N film coating has good cytocompatibility and blood compatibility and it is a promising approach for improvement of biocompatibility of biomaterial surfaces.
UR - http://www.scopus.com/inward/record.url?scp=84892425439&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84892425439&partnerID=8YFLogxK
U2 - 10.1557/opl.2013.12
DO - 10.1557/opl.2013.12
M3 - Conference contribution
AN - SCOPUS:84892425439
SN - 9781605114750
T3 - Materials Research Society Symposium Proceedings
SP - 103
EP - 108
BT - Biomimetic, Bio-Inspired and Self-Assembled Materials for Engineered Surfaces and Applications
T2 - 2012 MRS Fall Meeting
Y2 - 25 November 2012 through 30 November 2012
ER -